SENSITIVE, INDIRECT PHOTOMETRIC DETECTOR FOR HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY USING A LIGHT-EMITTING DIODE

被引:14
作者
BERTHOD, A [1 ]
GLICK, M [1 ]
WINEFORDNER, JD [1 ]
机构
[1] UNIV FLORIDA,DEPT CHEM,GAINESVILLE,FL 32611
来源
JOURNAL OF CHROMATOGRAPHY | 1990年 / 502卷 / 02期
关键词
D O I
10.1016/S0021-9673(01)89595-9
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A low-noise detector for indirect photometric detection has been constructed using a highly stable source -a light-emitting diode (LED). Use of the detector is demonstrated for reversed-phase liquid chromatography by adding methylene blue to the mobile phase to make a background signal. The indirect determination of alcohols by their effect on methylene blue concentration distribution is demonstrated, and an investigation is made into the conditions for high sensitivity. Because the source exhibits low noise, the detection limits for alcohols are as low as more complex and expensive detection methods, despite the lower radiant power of the LED. Detection limits for nine alcohols are below μg injected amounts. © 1990.
引用
收藏
页码:305 / 315
页数:11
相关论文
共 19 条
[11]   HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY OF LOW-MOLECULAR-WEIGHT ALIPHATIC-ALCOHOLS USING INDIRECT PHOTOMETRIC DETECTION [J].
PARKIN, JE ;
LAU, HT .
JOURNAL OF CHROMATOGRAPHY, 1984, 314 (NOV) :488-494
[12]   INDIRECT DETECTION IN HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY [J].
SCHILL, G ;
CROMMEN, J .
TRAC-TRENDS IN ANALYTICAL CHEMISTRY, 1987, 6 (05) :111-116
[13]   HIGH-PRECISION FLUORIMETRY WITH A LIGHT-EMITTING DIODE SOURCE [J].
SMITH, BW ;
JONES, BT ;
WINEFORDNER, JD .
APPLIED SPECTROSCOPY, 1988, 42 (08) :1469-1472
[14]   MECHANISTIC INTERPRETATIONS AND SIMULATIONS OF INDUCED PEAKS IN LIQUID-CHROMATOGRAPHY [J].
STRANAHAN, JJ ;
DEMING, SN .
ANALYTICAL CHEMISTRY, 1982, 54 (09) :1540-1546
[15]  
SU SY, 1981, ANAL LETT PT A, V14, P1
[16]   DETERMINATION OF POLYNUCLEAR AROMATIC-HYDROCARBONS BY A SPIKED MOBILE PHASE FLUORESCENCE HPLC DETECTOR [J].
SU, SY ;
LAI, EPC ;
WINEFORDNER, JD .
ANALYTICAL LETTERS PART A-CHEMICAL ANALYSIS, 1982, 15 (05) :439-450
[17]   DOUBLE-BEAM LASER-EXCITED INDIRECT FLUOROMETRIC DETECTION OF NONELECTROLYTES IN REVERSED-PHASE HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY [J].
TAKEUCHI, T ;
YEUNG, ES .
JOURNAL OF CHROMATOGRAPHY, 1986, 366 :145-152
[18]   MECHANISTIC STUDY OF THE NEGATIVE MODE FLUORESCENCE HPLC DETECTOR [J].
TORRES, EL ;
VANGEEL, F ;
WINEFORDNER, JD .
ANALYTICAL LETTERS PART A-CHEMICAL ANALYSIS, 1983, 16 (15) :1207-1218
[19]   INDIRECT UV DETECTION OF NON-ABSORBING SOLUTES IN REVERSED-PHASE HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY WITH THE HELP OF UV-ACTIVE, NON-IONIC MOBILE PHASE CONSTITUENTS [J].
VIGH, G ;
LEITOLD, A .
JOURNAL OF CHROMATOGRAPHY, 1984, 312 (NOV) :345-356