POTENTIAL DIAGNOSIS OF HEMODYNAMIC ABNORMALITIES IN PATENT DUCTUS-ARTERIOSUS BY CINE MAGNETIC-RESONANCE-IMAGING

被引:5
作者
CHIEN, CT
LIN, CS
HSU, YH
LIN, MC
CHEN, KS
WU, DJ
机构
[1] CHUNG SHAN MED & DENT COLL HOSP,DEPT INTERNAL MED,TAICHUNG,TAIWAN
[2] CHUNG SHAN MED & DENT COLL HOSP,DEPT PEDIAT,TAICHUNG,TAIWAN
关键词
D O I
10.1016/0002-8703(91)90473-U
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Cine magnetic resonance imaging was performed in 11 patients with communication between systemic and pulmonary circulation. In five patients with uncomplicated patent ductus arteriosus (PDA), ductus arteriosus was delineated by a persistent band of low signal intensity, whereas in two patients who also had severe pulmonary hypertension the signal intensity was varied. Two separate low signal intensities in the main pulmonary artery and the descending aorta were each uniformly recorded in the five patients with uncomplicated PDA, consistent with continuous left-to-right shunt and turbulent flow acceleration, respectively. In one of the patients with severe pulmonary hypertension but not Eisenmenger's syndrome, the areas of low signal intensity from left-to-right shunt and turbulent flow acceleration diminished. In the patient with Eisemenger's PDA the right-to-left shunt was also characterized by an area of low signal intensity but with a reversal in direction. Cine MR imaging has the potential to be a noninvasive and supplemental method for evaluating PDA.
引用
收藏
页码:1065 / 1073
页数:9
相关论文
共 33 条
[1]  
BANSAL RC, 1980, MAYO CLIN PROC, V55, P291
[2]   PULMONARY-ARTERY DISTENSIBILITY AND BLOOD-FLOW PATTERNS - A MAGNETIC-RESONANCE STUDY OF NORMAL SUBJECTS AND OF PATIENTS WITH PULMONARY ARTERIAL-HYPERTENSION [J].
BOGREN, HG ;
KLIPSTEIN, RH ;
MOHIADDIN, RH ;
FIRMIN, DN ;
UNDERWOOD, SR ;
REES, RSO ;
LONGMORE, DB .
AMERICAN HEART JOURNAL, 1989, 118 (05) :990-999
[3]   QUANTITATION OF ANTEGRADE AND RETROGRADE BLOOD-FLOW IN THE HUMAN AORTA BY MAGNETIC-RESONANCE VELOCITY MAPPING [J].
BOGREN, HG ;
KLIPSTEIN, RH ;
FIRMIN, DN ;
MOHIADDIN, RH ;
UNDERWOOD, SR ;
REES, RSO ;
LONGMORE, DB .
AMERICAN HEART JOURNAL, 1989, 117 (06) :1214-1222
[4]   ASSESSMENT OF AORTIC-INSUFFICIENCY BY TRANSCUTANEOUS DOPPLER ULTRASOUND [J].
BOUGHNER, DR .
CIRCULATION, 1975, 52 (05) :874-879
[5]  
EDWARDS JE, 1979, CARDIAC CLIN SERIES, V101, P1
[6]   EFFECTS OF TURBULENCE ON SIGNAL INTENSITY IN GRADIENT ECHO IMAGES [J].
EVANS, AJ ;
BLINDER, RA ;
HERFKENS, RJ ;
SPRITZER, CE ;
KUETHE, DO ;
FRAM, EK ;
HEDLUND, LW .
INVESTIGATIVE RADIOLOGY, 1988, 23 (07) :512-518
[7]  
FEIGENBAUM H, 1986, ECHOCARDIOGR-J CARD, P365
[8]  
GROSCH W, 1986, CHEM PHYSICS BAKING, P155
[9]   ACCURACY OF 2-DIMENSIONAL ECHOCARDIOGRAPHY IN THE DIAGNOSIS OF CONGENITAL HEART-DISEASE [J].
GUTGESELL, HP ;
HUHTA, JC ;
LATSON, LA ;
HUFFINES, D ;
MCNAMARA, DG .
AMERICAN JOURNAL OF CARDIOLOGY, 1985, 55 (05) :514-518
[10]  
HATLE L, 1985, DOPPLER ULTRASOUND C, P217