SYSTEM-ANALYSIS OF THE DYNAMIC-RESPONSE OF THE CORONARY CIRCULATION TO A SUDDEN CHANGE IN HEART-RATE

被引:10
作者
DANKELMAN, J
STASSEN, HG
SPAAN, JAE
机构
[1] UNIV AMSTERDAM,FAC MED,DEPT MED PHYS,MEIBERGDREEF 15,1105 AZ AMSTERDAM,NETHERLANDS
[2] DELFT UNIV TECHNOL,FAC MECH ENGN & MARINE TECHNOL,MEASUREMENT & CONTROL LAB,2620 CD DELFT,NETHERLANDS
关键词
Coronary circulation; Dynamics of regulation; Heart rate; Mathematical model;
D O I
10.1007/BF02441769
中图分类号
TP39 [计算机的应用];
学科分类号
081203 ; 0835 ;
摘要
In this study the response of driving pressure/flow ratio on an abrupt change in heart rate was analysed. The difference between the response obtained with constant pressure and constant flow perfusion was also studied. The responses show a fast initial reversed phase followed by a slow phase caused by regulation. To test whether the initial phase could be the result of mechanical changes in the coronary circulation, a model for regulation was extended by the addition of four different mechanical models originating from the literature. These extended models were able to explain the fast initial phase. However, the mechanical model consisting of an intramyocardial compliance (C=0·08 ml mm Hg-1 100 g-1) with a variable venous resistance, and the model consisting of a waterfall and a small compliance (C=0·007 ml mm Hg-1 100 g-1) both explained these responses best. The analysis showed that there is no direct relationship between rate of change of vascular tone and rate of change of pressure/flow ratio. However, on the basis of the two extended models, it can be predicted that the half-time for the response of regulation to be complete is about 9s with constant pressure perfusion and 15 s with constant flow perfusion. © 1990 IFMBE.
引用
收藏
页码:139 / 148
页数:10
相关论文
共 16 条
[11]   FORWARD CORONARY FLOW NORMALLY SEEN IN SYSTOLE IS THE RESULT OF BOTH FORWARD AND CONCEALED BACK FLOW [J].
SPAAN, JAE ;
BREULS, NPW ;
LAIRD, JD .
BASIC RESEARCH IN CARDIOLOGY, 1981, 76 (05) :582-586
[12]   DIASTOLIC-SYSTOLIC CORONARY FLOW DIFFERENCES ARE CAUSED BY INTRAMYOCARDIAL PUMP ACTION IN THE ANESTHETIZED DOG [J].
SPAAN, JAE ;
BREULS, NPW ;
LAIRD, JD .
CIRCULATION RESEARCH, 1981, 49 (03) :584-593
[13]   CORONARY DIASTOLIC PRESSURE-FLOW RELATION AND ZERO FLOW PRESSURE EXPLAINED ON THE BASIS OF INTRAMYOCARDIAL COMPLIANCE [J].
SPAAN, JAE .
CIRCULATION RESEARCH, 1985, 56 (03) :293-309
[14]  
SPAAN JAE, 1986, P IEEE MED BIOL, V1, P191
[15]   RATE OF DECREASE OF MYOCARDIAL O-2 CONSUMPTION DUE TO CARDIAC-ARREST IN ANESTHETIZED GOATS [J].
VERGROESEN, I ;
SPAAN, JAE .
PFLUGERS ARCHIV-EUROPEAN JOURNAL OF PHYSIOLOGY, 1988, 413 (02) :160-166
[16]   QUANTIFICATION OF O-2 CONSUMPTION AND ARTERIAL-PRESSURE AS INDEPENDENT DETERMINANTS OF CORONARY FLOW [J].
VERGROESEN, I ;
NOBLE, MIM ;
WIERINGA, PA ;
SPAAN, JAE .
AMERICAN JOURNAL OF PHYSIOLOGY, 1987, 252 (03) :H545-H553