PATIENT AND STAFF EXPOSURE TO GLUTARALDEHYDE FROM KEYMED AUTO-DISINFECTOR ENDOSCOPE WASHING MACHINE

被引:10
作者
LYNCH, DAF [1 ]
PARNELL, P [1 ]
PORTER, C [1 ]
AXON, ATR [1 ]
机构
[1] GEN INFIRM,DEPT INFECT CONTROL,LEEDS LS1 3EX,W YORKSHIRE,ENGLAND
关键词
D O I
10.1055/s-2007-1008991
中图分类号
R57 [消化系及腹部疾病];
学科分类号
摘要
Activated glutaraldehyde (2 %) is the recommended agent for disinfection of endoscopic equipment. Exposure to the disinfectant is associated with side-effects and guidelines have been set to avoid these complications. Endoscope washing machines are used to provide automated high level disinfection of endoscopes as well as reduce exposure to the irritant aldehyde. We report a design fault in an endoscope washing machine which results in patients and staff being exposed to activated glutaraldehyde. The Auto-Disinfector (KeyMed) comprises a washing chamber supplied by three separate reservoirs (detergent, disinfectant, and rinse water) via a common channel. After the first cycle endoscopes are processed using previously used detergent and rinse water. Rinse water glutaraldehyde concentrations were measured in four machines during routine endoscopy lists on at least two occasions and showed a progressive rise in glutaraldehyde concentration up to 0.1 % after two to six cycles. This results in staff being exposed to glutaraldehyde present on the processed instrument and the disinfectant being pumped from the internal channels of the endoscope into direct contact with the gastrointestinal mucosa during endoscopy at concentrations of 200-1000 ppm. The present atmospheric limit for glutaraldehyde is 0.2 ppm. Skin and mucosal irritation occur at concentrations of 0.3 ppm and severe synovitis in experimental animals at 100 pm. Tongue swelling and bloody diarrhoea with characteristic mucosal histological changes have been reported in patients exposed to activated glutaraldehyde on inadequately rinsed equipment. To reduce this problem the rinse water should be changed after every cycle and the endoscope should be dried thoroughly before use.
引用
收藏
页码:359 / 361
页数:3
相关论文
共 16 条
[1]  
AXON ATR, 1981, LANCET, V1, P1093
[2]   CLEANING AND DISINFECTION OF FLEXIBLE ENDOSCOPES AND ANCILLARY EQUIPMENT - USE OF AUTOMATIC DISINFECTORS [J].
BOTTRILL, PM ;
AXON, ATR .
JOURNAL OF GASTROENTEROLOGY AND HEPATOLOGY, 1991, 6 (01) :45-47
[3]  
CAMPBELL HM, 1991, HLTH ESTATE J, V45, P2
[4]  
De Rop H, 1991, Gastroenterol Nurs, V14, P27
[5]   INVESTIGATION OF AN OUTBREAK OF BLOODY DIARRHEA - ASSOCIATION WITH ENDOSCOPIC CLEANING SOLUTION AND DEMONSTRATION OF LESIONS IN AN ANIMAL-MODEL [J].
DURANTE, L ;
ZULTY, JC ;
ISRAEL, E ;
POWERS, PJ ;
RUSSELL, RG ;
QIZILBASH, AH ;
MORRIS, JG .
AMERICAN JOURNAL OF MEDICINE, 1992, 92 (05) :476-480
[6]   DISINFECTION AND ENDOSCOPY - PROCEDURES AND STAFF SAFETY [J].
FLEISHER, DE .
JOURNAL OF GASTROENTEROLOGY AND HEPATOLOGY, 1991, 6 (01) :41-43
[8]  
GRIGSBY EJ, 1991, CAN J ANAESTH, P826
[9]   CIDEX-INDUCED SYNOVITIS [J].
HARNER, CD ;
FU, FH ;
MASON, GC ;
WISSINGER, HA ;
RABIN, BS .
AMERICAN JOURNAL OF SPORTS MEDICINE, 1989, 17 (01) :96-102
[10]  
JACHUCK SJ, 1989, J SOC OCCUP MED, V39, P69