CYCLIC VOLTAMMETRY OF FERROCENECARBOXYLIC ACID MONOMOLECULAR FILMS AND THEIR REACTION WITH GLUCOSE-OXIDASE

被引:11
作者
BARMIN, AV [1 ]
EREMENKO, AV [1 ]
KUROCHKIN, IN [1 ]
SOKOLOVSKY, AA [1 ]
机构
[1] RES CTR MOLEC DIAGNOST & THERAPY,DEPT BIOSENSORS,MOSCOW 113149,RUSSIA
关键词
LANGMUIR-BLODGETT FILMS; FERROCENE DERIVATIVES; AMPHIPHILIC POLYMERS; CYCLIC VOLTAMMETRY; GLUCOSE OXIDASE;
D O I
10.1002/elan.1140060206
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Monomolecular films of ferrocene derivatives (FD) and of glucose oxidase (GOD) have been formed on a graphite electrode by the Langmuir-Schaefer (LS) method with the help of amphiphilic polymers. Cyclic voltammograms of these films and of their interaction with glucose oxidase were studied. Ferrocenecarboxylic acid, incorporated into polymeric matrices by adsorption to a monomolecular polymer film or by the direct mixing with a polymer solution before LB-film formation: retain their mediator properties in the reaction with GOD, The amperometric response of a graphite electrode with immobilized multilayer films containing polymer matrices, ferrocenecarboxylic acid and GOD were linear over the range 1-20 mM of glucose.
引用
收藏
页码:107 / 112
页数:6
相关论文
共 17 条
[1]   AMPEROMETRIC BIOSENSORS FOR GLUCOSE BASED ON CARBON PASTE MODIFIED ELECTRODES [J].
AMINE, A ;
KAUFFMANN, JM ;
PATRIARCHE, GJ .
TALANTA, 1991, 38 (01) :107-110
[2]   FERROCENE-MEDIATED ENZYME ELECTRODE FOR AMPEROMETRIC DETERMINATION OF GLUCOSE [J].
CASS, AEG ;
DAVIS, G ;
FRANCIS, GD ;
HILL, HAO ;
ASTON, WJ ;
HIGGINS, IJ ;
PLOTKIN, EV ;
SCOTT, LDL ;
TURNER, APF .
ANALYTICAL CHEMISTRY, 1984, 56 (04) :667-671
[3]   SUBCUTANEOUS IMPLANTATION OF A FERROCENE-MEDIATED GLUCOSE SENSOR IN PIGS [J].
CLAREMONT, DJ ;
SAMBROOK, IE ;
PENTON, C ;
PICKUP, JC .
DIABETOLOGIA, 1986, 29 (11) :817-821
[4]   POTENTIALLY-IMPLANTABLE, FERROCENE-MEDIATED GLUCOSE SENSOR [J].
CLAREMONT, DJ ;
PENTON, C ;
PICKUP, JC .
JOURNAL OF BIOMEDICAL ENGINEERING, 1986, 8 (03) :272-274
[5]   DIRECT ELECTRICAL COMMUNICATION BETWEEN CHEMICALLY MODIFIED ENZYMES AND METAL-ELECTRODES .2. METHODS FOR BONDING ELECTRON-TRANSFER RELAYS TO GLUCOSE-OXIDASE AND D-AMINO-ACID OXIDASE [J].
DEGANI, Y ;
HELLER, A .
JOURNAL OF THE AMERICAN CHEMICAL SOCIETY, 1988, 110 (08) :2615-2620
[6]   DIRECT ELECTRICAL COMMUNICATION BETWEEN CHEMICALLY MODIFIED ENZYMES AND METAL-ELECTRODES .1. ELECTRON-TRANSFER FROM GLUCOSE-OXIDASE TO METAL-ELECTRODES VIA ELECTRON RELAYS, BOUND COVALENTLY TO THE ENZYME [J].
DEGANI, Y ;
HELLER, A .
JOURNAL OF PHYSICAL CHEMISTRY, 1987, 91 (06) :1285-1289
[7]  
EREMENKO AV, IN PRESS THIN SOLID
[8]   ELECTRODES MODIFIED WITH NAFION FILMS INCORPORATING AMPHIPHILIC FERROCENE DERIVATIVES [J].
GARCIA, O ;
KAIFER, AE .
JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 1990, 279 (1-2) :79-94
[9]   AMPEROMETRIC GLUCOSE SENSORS BASED ON FERROCENE-MODIFIED POLY(ETHYLENE OXIDE) AND GLUCOSE-OXIDASE [J].
HALE, PD ;
LAN, HL ;
BOGUSLAVSKY, LI ;
KARAN, HI ;
OKAMOTO, Y ;
SKOTHEIM, TA .
ANALYTICA CHIMICA ACTA, 1991, 251 (1-2) :121-128
[10]   MEDIATED ELECTRON-TRANSFER FROM GLUCOSE-OXIDASE AT A FERROCENE-MODIFIED GRAPHITE ELECTRODE [J].
JONSSON, G ;
GORTON, L ;
PETTERSSON, L .
ELECTROANALYSIS, 1989, 1 (01) :49-55