HIGHLY SENSITIVE AND RAPID-DETERMINATION OF THEOPHYLLINE, THEOBROMINE AND CAFFEINE IN HUMAN PLASMA AND URINE BY GRADIENT CAPILLARY HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY FRIT-FAST ATOM BOMBARDMENT MASS-SPECTROMETRY

被引:27
作者
HIEDA, Y
KASHIMURA, S
HARA, K
KAGEURA, M
机构
[1] Department of Forensic Medicine, Fukuoka University School of Medicine, Jonan-ku, Fukuoka, 814-80
来源
JOURNAL OF CHROMATOGRAPHY B-BIOMEDICAL APPLICATIONS | 1995年 / 667卷 / 02期
关键词
D O I
10.1016/0378-4347(95)00028-H
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
A sensitive and reliable analytical procedure has been established for the detection of theophylline (TH), theobromine (TB) and caffeine (CA) in human plasma and urine by gradient capillary high-performance liquid chromatography (HPLC)-frit-fast atom bombardment mass spectrometry (FAB-MS) (LC-frit-FAB-MS), Two capillary columns and a column-switching valve were used in this LC system to allow all of the sample injected to be introduced into the MS system. 7-Ethyltheophylline was used as the internal standard (I.S.). The xanthines in the specimen were extracted with an Extrelut column. The lowest detected amount was ca. 5 ng/ml using this method.
引用
收藏
页码:241 / 246
页数:6
相关论文
共 8 条
[1]  
ARAMAKI S, 1991, CHEM PHARM BULL, V39, P2999, DOI 10.1248/cpb.39.2999
[2]   THEOPHYLLINE ANALYSIS AT THE CHEST CLINIC - COMPARISON OF A PORTABLE VERSUS CONVENTIONAL SYSTEM [J].
BALDWIN, DR ;
BERG, JD ;
BUCKLEY, BM ;
MACKAY, AD .
RESPIRATORY MEDICINE, 1991, 85 (01) :21-25
[3]   HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHIC DETERMINATION OF THEOPHYLLINE AND ITS DERIVATIVES WITH ELECTROCHEMICAL DETECTION [J].
GREENBERG, MS ;
MAYER, WJ .
JOURNAL OF CHROMATOGRAPHY, 1979, 169 (FEB) :321-327
[4]   SIMULTANEOUS ANALYSIS OF THEOPHYLLINE, CAFFEINE AND 8 OF THEIR METABOLIC PRODUCTS IN HUMAN PLASMA BY GRADIENT HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY [J].
LEAKEY, TEB .
JOURNAL OF CHROMATOGRAPHY, 1990, 507 :199-220
[5]   DETERMINATION OF THEOPHYLLINE IN SERUM AND SALIVA IN THE PRESENCE OF CAFFEINE AND ITS METABOLITES [J].
MONCRIEFF, J .
JOURNAL OF CHROMATOGRAPHY-BIOMEDICAL APPLICATIONS, 1991, 568 (01) :177-185
[6]   CHARACTERISTICS OF A LIQUID CHROMATOGRAPH ATMOSPHERIC-PRESSURE IONIZATION MASS-SPECTROMETER [J].
SAKAIRI, M ;
KAMBARA, H .
ANALYTICAL CHEMISTRY, 1988, 60 (08) :774-780
[7]   RAPID HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY ASSAY FOR SALIVARY AND SERUM CAFFEINE FOLLOWING AN ORAL LOAD - AN INDICATOR OF LIVER-FUNCTION [J].
SETCHELL, KDR ;
WELSH, MB ;
KLOOSTER, MJ ;
BALISTRERI, WF ;
LIM, CK .
JOURNAL OF CHROMATOGRAPHY, 1987, 385 :267-274
[8]   SIMULTANEOUS DETERMINATION OF CAFFEINE AND ITS PRIMARY DEMETHYLATED METABOLITES IN HUMAN PLASMA BY HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY [J].
TANAKA, E .
JOURNAL OF CHROMATOGRAPHY-BIOMEDICAL APPLICATIONS, 1992, 575 (02) :311-314