COMPARISON BETWEEN TL-201 AND TC-99M METHOXYISOBUTYL ISONITRILE DEFECT SIZE IN SINGLE-PHOTON EMISSION COMPUTED-TOMOGRAPHY AT REST, EXERCISE AND REDISTRIBUTION IN CORONARY-ARTERY DISEASE

被引:43
作者
MAUBLANT, JC
MARCAGGI, X
LUSSON, JR
BOIRE, JY
CAUVIN, JC
JACOB, P
VEYRE, A
CASSAGNES, J
机构
[1] INSERM,U7U,ETUD & RECH IMAGERIE MED GRP,CLERMONT FERRAND,FRANCE
[2] CTR HOSP REG & UNIV ST JACQUES,DEPT CARDIOL,CLERMONT FERRAND,FRANCE
关键词
D O I
10.1016/0002-9149(92)91302-K
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Defect size on myocardial tomograms was measured in 30 patients who underwent 2 separate studies, 1 with thallium-201 (TI-201), the other with technetium-99m-methoxyisobutyl isonitrile (MIBI). A group of 15 patients with myocardial infarction was studied at rest and received both tracers on the same day. The other 15 patients had documented coronary artery disease. They were were given injections of TI-201 at peak exercise and underwent imaging immediately after exercise and again 4 hours later. They then received a dose of MIBI for imaging at rest. A week later they underwent a second exercise test with the same work load and received a second dose of MIBI. Defect size on single-photon emission computed tomographic images was measured and repeated twice. Results were expressed in percentage of the volume of the whole myocardium. Reproducibility of the defect size measurement was high for TI-201 (r = 0.978; SEE = 1.59) as well as for MIBI (r = 0.981; SEE = 0.80). In patients with coronary artery disease the mean size of the defects was significantly larger with TI-201 than with MIBI at exercise (6.7 +/- 5.2 vs 4.6 +/- 5.2%, respectively, p < 0.05) and at redistribution (5.1 +/- 4.4 vs 2.8 +/- 3.2%, respectively, p < 0.05), where no difference was seen in patients with myocardial infarction studied only at rest (11.2 +/- 10.4 vs 12.0 +/- 11.5%, respectively, p = not significant). Smaller MIBI defect sizes, when compared with TI-201, in the exercise and redistribution studies were not due to technical artefacts since there was no difference when they were compared at rest.
引用
收藏
页码:183 / 187
页数:5
相关论文
共 18 条
  • [1] ARE THE KINETICS OF TC-99M METHOXYISOBUTYL ISONITRILE AFFECTED BY CELL-METABOLISM AND VIABILITY
    BEANLANDS, RSB
    DAWOOD, F
    WEN, WH
    MCLAUGHLIN, PR
    BUTANY, J
    DAMATI, G
    LIU, PP
    [J]. CIRCULATION, 1990, 82 (05) : 1802 - 1814
  • [2] RELATIONS OF THE MYOCARDIAL IMAGING AGENTS TC-99M-MIBI AND TL-201 TO MYOCARDIAL BLOOD-FLOW IN A CANINE MODEL OF MYOCARDIAL ISCHEMIC INSULT
    CANBY, RC
    SILBER, S
    POHOST, GM
    [J]. CIRCULATION, 1990, 81 (01) : 289 - 296
  • [3] FARRAGI M, 1989, NUCL MED COMMUN, V10, P539
  • [4] FREEMAN I, 1991, J NUCL MED, V32, P292
  • [5] TECHNICAL ASPECTS OF MYOCARDIAL SPECT IMAGING WITH TC-99M SESTAMIBI
    GARCIA, EV
    COOKE, CD
    VANTRAIN, KF
    FOLKS, R
    PEIFER, J
    DEPUEY, EG
    MADDAHI, J
    ALAZRAKI, N
    GALT, J
    EZQUERRA, N
    ZIFFER, J
    AREEDA, J
    BERMAN, DS
    [J]. AMERICAN JOURNAL OF CARDIOLOGY, 1990, 66 (13) : E23 - E31
  • [6] GEHRING PJ, 1967, J PHARMACOL EXP THER, V155, P187
  • [7] QUANTITATIVE ROTATIONAL TOMOGRAPHY WITH TL-201 AND TC-99M 2-METHOXY-ISOBUTYL-ISONITRILE - A DIRECT COMPARISON IN NORMAL INDIVIDUALS AND PATIENTS WITH CORONARY-ARTERY DISEASE
    KAHN, JK
    MCGHIE, I
    AKERS, MS
    SILLS, MN
    FABER, TL
    KULKARNI, PV
    WILLERSON, JT
    CORBETT, JR
    [J]. CIRCULATION, 1989, 79 (06) : 1282 - 1293
  • [8] COMPARISON OF TECHNETIUM-99M METHOXY ISOBUTYL ISONITRILE AND TL-201 FOR EVALUATION OF CORONARY-ARTERY DISEASE BY PLANAR AND TOMOGRAPHIC METHODS
    KIAT, H
    MADDAHI, J
    ROY, LT
    VANTRAIN, K
    FRIEDMAN, J
    RESSER, K
    BERMAN, DS
    [J]. AMERICAN HEART JOURNAL, 1989, 117 (01) : 1 - 11
  • [9] LEPPO JA, 1986, J NUCL MED, V27, P66
  • [10] QUANTIFICATION OF INFARCT SIZE IN THE DOG BY TL-201 SINGLE PHOTON-EMISSION TRANSAXIAL TOMOGRAPHY (SPETT)
    MAUBLANT, J
    GACHON, P
    MOINS, N
    DUCHENEMARULLAZ, P
    [J]. EUROPEAN HEART JOURNAL, 1983, 4 (04) : 272 - 279