BEAM CHARACTERISTICS OF A NEW-GENERATION 50 MEV RACETRACK MICROTRON

被引:14
作者
MASTERSON, ME
CHUI, CS
FEBO, R
HUNG, JD
FUKS, Z
MOHAN, R
LING, CC
KUTCHER, GJ
BJORK, S
ENSTROM, J
机构
[1] MEM SLOAN KETTERING CANC CTR,NEW YORK,NY 10021
[2] SCANDITRONIX AB,UPPSALA,SWEDEN
关键词
RADIOTHERAPY ACCELERATOR; RACETRACK MICROTRON; BEAM CHARACTERISTICS; DOSIMETRY;
D O I
10.1118/1.597587
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The first of a new generation of microtron accelerators has been installed and tested. It is currently in use for multisegment conformal radiotherapy at our institution. The unit produces x rays and electrons from 10 to 50 MeV in 5 MeV increments. It incorporates a 64 leaf, doubly focused multileaf collimator (MLC), which can be used to shape x-ray and electron beams. Both x-ray and electron beams are produced by magnetically scanning the electron beams from the accelerator. The new generation unit incorporates a purging magnet to sweep away any primary or secondary electrons that pass through the target(s). In this paper, the beam characteristics of the accelerator that were studied during acceptance testing are described. Representative examples of depth doses, beam profiles, output factors, and elementary beam distributions are presented and discussed, in comparison with the earlier generation of microtron accelerators and with other radiotherapy machines. © 1995, American Association of Physicists in Medicine. All rights reserved.
引用
收藏
页码:781 / 792
页数:12
相关论文
共 25 条
[1]   DEPTH DOSE AND STOPPING-POWER DATA FOR MONOENERGETIC ELECTRON-BEAMS [J].
ANDREO, P .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 1990, 51 (02) :107-121
[2]  
[Anonymous], 1983, MED PHYS, V10, P741
[3]  
Biggs P J, 1979, Med Phys, V6, P291, DOI 10.1118/1.594580
[4]  
Bova F J, 1990, Med Dosim, V15, P83
[5]   PHYSICAL AND BIOLOGIC ASPECTS ON THE OPTIMUM CHOICE OF RADIATION MODALITY [J].
BRAHME, A .
ACTA RADIOLOGICA ONCOLOGY, 1982, 21 (06) :469-479
[6]   DESIGN PRINCIPLES AND CLINICAL POSSIBILITIES WITH A NEW GENERATION OF RADIATION-THERAPY EQUIPMENT - A REVIEW [J].
BRAHME, A .
ACTA ONCOLOGICA, 1987, 26 (06) :403-412
[7]   ANGULAR-DISTRIBUTION OF BREMSSTRAHLUNG FROM 15-MEV ELECTRONS INCIDENT ON THICK TARGETS OF BE, AL, AND PB [J].
FADDEGON, BA ;
ROSS, CK ;
ROGERS, DWO .
MEDICAL PHYSICS, 1991, 18 (04) :727-739
[8]   SURFACE DOSE FROM MEGAVOLTAGE THERAPY MACHINES [J].
GAGNON, WF ;
GRANT, W .
RADIOLOGY, 1975, 117 (03) :705-708
[9]   OFF-AXIS BEAM QUALITY CHANGE IN LINEAR-ACCELERATOR X-RAY-BEAMS [J].
HANSON, WF ;
BERKLEY, LW ;
PETERSON, M .
MEDICAL PHYSICS, 1980, 7 (02) :145-146
[10]   CALCULATIVE TECHNIQUE TO CORRECT FOR THE CHANGE IN LINEAR-ACCELERATOR BEAM ENERGY AT OFF-AXIS POINTS [J].
HANSON, WF ;
BERKLEY, LW ;
PETERSON, M .
MEDICAL PHYSICS, 1980, 7 (02) :147-150