PRELIMINARY-RESULTS OF A QUALITY ASSURANCE NETWORK FOR RADIOTHERAPY CENTERS IN EUROPE

被引:25
作者
DUTREIX, A [1 ]
VANDERSCHUEREN, E [1 ]
DERREUMAUX, S [1 ]
CHAVAUDRA, J [1 ]
机构
[1] INST GUSTAVE ROUSSY, DEPT PHYS, F-94805 VILLEJUIF, FRANCE
关键词
QUALITY ASSURANCE; DOSIMETRY INTERCOMPARISON; DOSIMETRY NETWORKS; RADIOTHERAPY INFRASTRUCTURE; MAILED DOSIMETRY;
D O I
10.1016/0167-8140(93)90232-W
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Based on the IAEA/WHO experience in mailed dosimetry, a Quality Assurance (QA) Network, sponsored by the EC committee ''Europe Against Cancer'', has been set up in 1991 for European centres, not involved in clinical research. Besides a survey of radiotherapy infrastructure, the project includes three measurement steps: primarily a check of beam output and quality in reference conditions with a mailed TLD-procedure, in a second step the mailed verification of other beam data and dose calculation procedures with a multipurpose phantom and finally in vivo dosimetry al the individual patient levels with mailed dosimeters. The results of infrastructure show good agreement with the data previously published by EORTC for research centres. Until January 1993, a total number of 37 centres (49 X-ray beams and 28 cobalt beams) from Belgium, France, Italy, The Netherlands, Sweden and The Czech and Slovak Republics have participated in the first measurement step. Deviations > 3% and < 6% from the stated dose are found in 17 out of the 79 checked beams. A deviation < 6% from the stated dose is detected in only I out of the 28 cobalt beams, but in 7 of the 49 X-ray beams. The large majority of the beams (23/25) with deviations > 3% belong to centres not having participated in external audits in the previous 5 years. A pilot study for the second step shows larger deviations in non reference conditions, especially for off-axis points and for oblique phantom surface. The third step has yet to be implemented. The initial stage of the project already demonstrates the usefulness of the programme especially for centres which have never before participated in external audits. Four more countries will join the programme and more centres are volunteering to participate than can be measured. A minimal central structure for the programme guarantees uniformity of procedures, interchangeable information, follow-up and joint resolution of specific technical problems.
引用
收藏
页码:97 / 101
页数:5
相关论文
共 20 条
[1]   POSTAL DOSE INTERCOMPARISON OF CO-60 DOSIMETRY USING THERMO-LUMINESCENCE DOSIMETERS AMONG SECONDARY STANDARD DOSIMETRY LABORATORIES [J].
BOYD, AW ;
EISENLOHR, HH ;
GIRZIKOWSKY, R .
MEDICAL PHYSICS, 1982, 9 (01) :112-113
[2]   WHEN AND HOW CAN WE IMPROVE PRECISION IN RADIOTHERAPY [J].
DUTREIX, A .
RADIOTHERAPY AND ONCOLOGY, 1984, 2 (04) :275-292
[3]  
HANSON WF, 1993, 1991 INT SEM EUR MID
[4]   A DOSIMETRIC QUALITY AUDIT OF PHOTON BEAMS BY THE BELGIAN-HOSPITAL-PHYSICIST-ASSOCIATION [J].
HOORNAERT, MT ;
VANDAM, J ;
VYNCKIER, S ;
BOUILLER, A .
RADIOTHERAPY AND ONCOLOGY, 1993, 28 (01) :37-43
[5]   QUALITY ASSURANCE CONTROL IN THE EORTC COOPERATIVE GROUP OF RADIOTHERAPY .1. ASSESSMENT OF RADIOTHERAPY STAFF AND EQUIPMENT [J].
HORIOT, JC ;
JOHANSSON, KA ;
GONZALEZ, DG ;
VANDERSCHUEREN, E ;
VANDENBOGAERT, W ;
NOTTER, G .
RADIOTHERAPY AND ONCOLOGY, 1986, 6 (04) :275-284
[6]  
JOHANSSON KA, 1982, ACTA RADIOL ONCOL, V21, P1
[7]   QUALITY ASSURANCE IN RADIOTHERAPY BY INVIVO DOSIMETRY .1. ENTRANCE DOSE MEASUREMENTS, A RELIABLE PROCEDURE [J].
LEUNENS, G ;
VANDAM, J ;
DUTREIX, A ;
VANDERSCHUEREN, E .
RADIOTHERAPY AND ONCOLOGY, 1990, 17 (02) :141-151
[8]   QUALITY ASSURANCE IN RADIOTHERAPY BY INVIVO DOSIMETRY .2. DETERMINATION OF THE TARGET ABSORBED DOSE [J].
LEUNENS, G ;
VANDAM, J ;
DUTREIX, A ;
VANDERSCHUEREN, E .
RADIOTHERAPY AND ONCOLOGY, 1990, 19 (01) :73-87
[9]   HUMAN ERRORS IN DATA TRANSFER DURING THE PREPARATION AND DELIVERY OF RADIATION TREATMENT AFFECTING THE FINAL RESULT - GARBAGE IN, GARBAGE OUT [J].
LEUNENS, G ;
VERSTRAETE, J ;
VANDENBOGAERT, W ;
VANDAM, J ;
DUTREIX, A ;
VANDERSCHUEREN, E .
RADIOTHERAPY AND ONCOLOGY, 1992, 23 (04) :217-222
[10]   INVIVO DOSIMETRY FOR TANGENTIAL BREAST IRRADIATION - ROLE OF THE EQUIPMENT IN THE ACCURACY OF DOSE DELIVERY [J].
LEUNENS, G ;
VERSTRAETE, J ;
VANDAM, J ;
DUTREIX, A ;
VANDERSCHUEREN, E .
RADIOTHERAPY AND ONCOLOGY, 1991, 22 (04) :285-289