DOSE CALCULATIONS ABOUT SHIELDED GYNECOLOGICAL COLPOSTATS

被引:56
作者
WILLIAMSON, JF [1 ]
机构
[1] UNIV ARIZONA,DEPT RADIAT ONCOL,TUCSON,AZ 85724
来源
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS | 1990年 / 19卷 / 01期
关键词
!sup]137[!/sup]Cs; !sup]226[!/sup]Ra; Brachytherapy; Colpostats; Dosimetry; Intracavitary therapy; Monte Carlo;
D O I
10.1016/0360-3016(90)90150-I
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Although shielded gynecological colpostats have been shown experimentally to reduce doses to bladder and rectal tissue by as much as 50%, nearly all previously described dose computation algorithms ignore applicator heterogeneities. We describe the use of realistic Monte Carlo calculations to study the dosimetric effects of applicator structure. Use of sophisticated solid modeling techniques allows the complex internal structure of two commercially-available Fletcher-Suit colpostats, as well as that of 226Ra or 137Cs tubes, to be accurately simulated. Our results show significant differences among these source-applicator combinations. In addition, a novel dose computation algorithm for efficiently estimating absorbed dose near shielded applicators is described. Our approach is based upon empirical separation of primary- and scatter-dose components. The algorithm requires a small base of Monte Carlo-generated data, reproduces the Monte Carlo dose estimates within 3%, and is faster than Monte Carlo by a factor of 15,000. The scatter-separation method has the potential to make accurate dose estimates to bladder, rectum, tumor, and vagina available for clinical treatment planning and for extraction of more meaningful dose-response curves from clinical data. © 1990.
引用
收藏
页码:167 / 178
页数:12
相关论文
共 50 条
[1]   RADIATION TOLERANCE OF THE NORMAL TISSUES OF THE LARYNX - ITS IMPLICATIONS IN RADIOTHERAPY [J].
ARISTIZABAL, SA ;
CALDWELL, WL .
RADIOLOGY, 1972, 103 (02) :419-+
[2]  
BOYER A L, 1979, Medical Physics (Woodbury), V6, P454, DOI 10.1118/1.594537
[3]   DOSIMETRIC PRECISION REQUIREMENTS IN RADIATION-THERAPY [J].
BRAHME, A .
ACTA RADIOLOGICA ONCOLOGY, 1984, 23 (05) :379-391
[4]   CARCINOMA OF CERVIX - TIME DOSE ANALYSIS OF CONTROL AND COMPLICATIONS [J].
CHISM, SE ;
KEYS, HM ;
GILLIN, MT .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1975, 123 (01) :84-90
[5]   ROUTINE CLINICAL ESTIMATION OF RECTAL, RECTOSIGMOIDAL, AND BLADDER DOSES FROM INTRACAVITARY BRACHYTHERAPY IN THE TREATMENT OF CARCINOMA OF THE CERVIX [J].
CUNNINGHAM, DE ;
STRYKER, JA ;
VELKLEY, DE ;
CHUNG, CK .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1981, 7 (05) :653-660
[6]   EXPERIMENTAL AND CALCULATED DOSE DISTRIBUTION IN WATER AROUND CDC K-TYPE CESIUM-137 SOURCES [J].
DIFFEY, BL ;
KLEVENHAGEN, SC .
PHYSICS IN MEDICINE AND BIOLOGY, 1975, 20 (03) :446-454
[7]  
DILLMAN LT, 1975, RADIOACTIVE DECAY SC, P8
[8]  
Fletcher G, 1980, TXB RADIOTHERAPY, P732
[9]   CERVICAL RADIUM APPLICATORS WITH SCREENING IN THE DIRECTION OF BLADDER AND RECTUM [J].
FLETCHER, GH .
RADIOLOGY, 1953, 60 (01) :77-84
[10]   EVALUATION OF A NEW FLETCHER APPLICATOR USING CESIUM-137 [J].
HAAS, JS ;
DEAN, RD ;
MANSFIELD, CM .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1980, 6 (11) :1589-1595