MR MEASUREMENT OF BLOOD-FLOW IN THE CARDIOVASCULAR-SYSTEM

被引:96
作者
MOSTBECK, GH [1 ]
CAPUTO, GR [1 ]
HIGGINS, CB [1 ]
机构
[1] UNIV CALIF SAN FRANCISCO, DEPT RADIOL, BOX 0628, RM L308, 505 PARNASSUS ST, SAN FRANCISCO, CA 94143 USA
关键词
D O I
10.2214/ajr.159.3.1503004
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Methods for measurement of blood flow with MR were devised many years ago but have been used for diagnosis in only the past few years. The two methods of measurement that have been used most extensively are based on the principles of time of flight and phase shift. A number of factors can influence the accuracy of MR measurements of blood flow. In vitro studies using flow phantoms have verified the accuracy of the phase-shift technique for measuring flow velocities exceeding 5 m/sec, which for practical purposes, encompasses the peak flow encountered in cardiovascular disorders. The flow measurements have been used to quantify valvular heart disease, congenital heart disease, pulmonary arterial disease, thoracic aortic disease, and peripheral vascular disease.
引用
收藏
页码:453 / 461
页数:9
相关论文
共 71 条
[1]   AORTIC DISSECTION - MAGNETIC-RESONANCE IMAGING [J].
AMPARO, EG ;
HIGGINS, CB ;
HRICAK, H ;
SOLLITTO, R .
RADIOLOGY, 1985, 155 (02) :399-406
[2]  
AXEL L, 1986, Magnetic Resonance Imaging, V4, P199, DOI 10.1016/0730-725X(86)91059-3
[3]   BLOOD-FLOW EFFECTS IN MAGNETIC-RESONANCE IMAGING [J].
AXEL, L .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1984, 143 (06) :1157-1166
[4]   MAGNETIC-RESONANCE VELOCITY MAPPING IN AORTIC DISSECTION [J].
BOGREN, HG ;
UNDERWOOD, SR ;
FIRMIN, DN ;
MOHIADDIN, RH ;
KLIPSTEIN, RH ;
REES, RSO ;
LONGMORE, DB .
BRITISH JOURNAL OF RADIOLOGY, 1988, 61 (726) :456-462
[5]   THE FUNCTION OF THE AORTA IN ISCHEMIC HEART-DISEASE - A MAGNETIC-RESONANCE AND ANGIOGRAPHIC STUDY OF AORTIC COMPLIANCE AND BLOOD-FLOW PATTERNS [J].
BOGREN, HG ;
MOHIADDIN, RH ;
KLIPSTEIN, RK ;
FIRMIN, DN ;
UNDERWOOD, RS ;
REES, SR ;
LONGMORE, DB .
AMERICAN HEART JOURNAL, 1989, 118 (02) :234-247
[6]   PULMONARY-ARTERY DISTENSIBILITY AND BLOOD-FLOW PATTERNS - A MAGNETIC-RESONANCE STUDY OF NORMAL SUBJECTS AND OF PATIENTS WITH PULMONARY ARTERIAL-HYPERTENSION [J].
BOGREN, HG ;
KLIPSTEIN, RH ;
MOHIADDIN, RH ;
FIRMIN, DN ;
UNDERWOOD, SR ;
REES, RSO ;
LONGMORE, DB .
AMERICAN HEART JOURNAL, 1989, 118 (05) :990-999
[7]   QUANTITATION OF ANTEGRADE AND RETROGRADE BLOOD-FLOW IN THE HUMAN AORTA BY MAGNETIC-RESONANCE VELOCITY MAPPING [J].
BOGREN, HG ;
KLIPSTEIN, RH ;
FIRMIN, DN ;
MOHIADDIN, RH ;
UNDERWOOD, SR ;
REES, RSO ;
LONGMORE, DB .
AMERICAN HEART JOURNAL, 1989, 117 (06) :1214-1222
[8]  
BOGREN HG, 1991, 1991 SOC MAGN RES ME, P968
[9]   BLOOD-FLOW - MAGNETIC-RESONANCE IMAGING [J].
BRADLEY, WG ;
WALUCH, V .
RADIOLOGY, 1985, 154 (02) :443-450
[10]  
BRENNER LD, 1991, 1991 SOC MAGN RES ME, P992