LONG-LASTING VENTILATORY RESPONSE OF HUMANS TO A SINGLE BREATH OF HYPERCAPNIA IN HYPEROXIA

被引:25
作者
MODARRESZADEH, M
BRUCE, EN
机构
[1] CASE WESTERN RESERVE UNIV,DEPT BIOMED ENGN,CLEVELAND,OH 44106
[2] CASE WESTERN RESERVE UNIV,DEPT MED,CLEVELAND,OH 44106
关键词
CENTRAL CHEMOREFLEX; TRANSIENT VENTILATION; CLOSED-LOOP RESPONSE; PSEUDORANDOM BINARY SEQUENCE;
D O I
10.1152/jappl.1992.72.1.242
中图分类号
Q4 [生理学];
学科分类号
071003 ;
摘要
It has often been assumed that under normoxia, closed-loop ventilatory responses to transient CO2 stimulation (i.e., lasting for 1-3 breaths) are less likely to be mediated by the slow-responding central (medullary) chemoreflex. This assumption, however, has not been quantitatively examined in humans. We hypothesized that in the closed-loop respiratory chemical feedback system [in which the centrally mediated ventilatory response to transient changes in the arterial PCO2 levels (Pa(CO2)) will in turn affect the pulmonary CO2 and hence Pa(CO2)], the contribution of the central chemoreflex pathways to brief disturbances in blood gases may be more important than considered previously. Using the technique of pseudorandom binary CO2 stimulation, we quantified the ventilatory response of normal humans to brief disturbances in arterial CO2 during hyperoxia. Tidal volume (VI), inspiratory ventilation (VI), inspiratory time (TI), expiratory time (TE), and end-tidal CO2 fraction (FET(CO2)) were measured in subjects who inhaled a mixture that was pseudorandomly switched between 95% O2-5% CO2 and 100% O2 (63 breath sequences). From these data, we calculated the responses of VI, VI, TI, TE, and FET(CO2), to a single-breath inhalation of 1% CO2 in O2. Our results showed that in response to a brief increase of 0.75 Torr in alveolar CO2, VI showed a transient increase (average peak response of 0.12 l/min) that persisted for greater-than-or-equal-to 80 s in every subject. The response of VI was similar to that of VI, whereas TI and TE showed no consistent changes. Using these results we calculated that central chemoreflex pathways may contribute significantly to typical transient CO2 stimulation tests in hyperoxic and normoxic humans.
引用
收藏
页码:242 / 250
页数:9
相关论文
共 26 条
[21]  
MODARRESZADEH M, 1990, FASEB Journal, V4, pA539
[22]   FREQUENCY-RESPONSE OF CAROTID-BODY CHEMORECEPTORS IN CAT TO CHANGES OF PACO2, PAO2, AND PHA [J].
PONTE, J ;
PURVES, MJ .
JOURNAL OF APPLIED PHYSIOLOGY, 1974, 37 (05) :635-647
[23]   THE VENTILATORY RESPONSE OF THE HUMAN RESPIRATORY SYSTEM TO SINE WAVES OF ALVEOLAR CARBON-DIOXIDE AND HYPOXIA [J].
ROBBINS, PA .
JOURNAL OF PHYSIOLOGY-LONDON, 1984, 350 (MAY) :461-474
[24]   REAL-TIME MOMENT ANALYSIS OF PULMONARY NITROGEN WASHOUT [J].
SANIIE, J ;
SAIDEL, GM ;
CHESTER, EH .
JOURNAL OF APPLIED PHYSIOLOGY, 1979, 46 (06) :1184-1190
[25]   PSEUDORANDOM TESTING OF VENTILATORY RESPONSE TO INSPIRED CARBON-DIOXIDE IN MAN [J].
SOHRAB, S ;
YAMASHIRO, SM .
JOURNAL OF APPLIED PHYSIOLOGY, 1980, 49 (06) :1000-1009
[26]  
SWANSON GD, 1975, J APPL PHYSIOL, V39, P337