CONFOUNDERS OF AUSCULTATORY BLOOD-PRESSURE MEASUREMENT

被引:13
作者
BAKER, RH [1 ]
ENDE, J [1 ]
机构
[1] HOSP UNIV PENN,DEPT AMBULATORY CARE EDUC,DIV GEN INTERNAL MED,PHILADELPHIA,PA 19104
关键词
D O I
10.1007/BF02600259
中图分类号
R19 [保健组织与事业(卫生事业管理)];
学科分类号
摘要
The appropriate use of any test requires the clinician to appreciate that test's limitations. By recognizing the potential confounders of the auscultatory assessment of blood pressure, the clinician minimizes the likelihood of enacting therapeutic decisions based on inaccurate data. When approaching the treatment of a hypertensive patient, several points should be kept in mind. First, the measurement of persistent and severe hypertension in a patient receiving treatment who describes symptoms of orthostatic hypotension with apparently adequate standing blood pressure or who lacks corroborating retinal, echocardiographic, or electrocardiographic signs of hypertension should raise the concern of pseudohypertension or a white-coat response. Similarly, when one finds a normal or near-normal systolic blood pressure in a patient with a clinical picture consistent with severe hypertension, one should make a directed effort to look for an unrecognized auscultatory gap. Second, marked discrepancies in measurements as obtained by different operators or in different settings should raise concern of the white-coat response or methodologic errors by one operator, such as undercuffing, excessive pressure on the head of the stethoscope, rapid deflation of the cuff, or use of different arms. In treating hypertension in even the minimally obese patient, a special point must be made that an adequate size cuff be used for all blood pressure determinations. Third, when blood pressure is determined with the patient in any but the standardized back-and-arm-sup-ported seated position described above, the clinician should acknowledge the possibility that the position may alter the patient's classification. Fourth, the diagnosis and management of hypertension requires multiple measurements of blood pressure. To the extent possible, measurements on different days or at different times should be taken with conditions as identical as possible so that differences seen result from therapeutic interventions and not methodologic differences. © 1995 Society of General Internal Medicine.
引用
收藏
页码:223 / 231
页数:9
相关论文
共 62 条
  • [21] Burch G.E., Shewey L., Sphygmomanometric cuff size and blood pressure recordings, JAMA: The Journal of the American Medical Association, 225, pp. 1215-8, (1973)
  • [22] Geddes L.A., Whistler S.J., The error in indirect blood pressure measurement with the incorrect size of cuff, Am Heart J, 96, pp. 4-8, (1978)
  • [23] King G.E., Taking the blood pressure, JAMA, 209, pp. 1902-4, (1969)
  • [24] Linfors E.W., Feussner J.R., Blessing C.L., Starmer F., Neelson F.A., McKee P.A., Spurious hypertension in the obese: effect of sphygmomanometer cuff size on prevalence of hypertension, Arch Intern Med, 144, pp. 1482-5, (1984)
  • [25] Prineas R.J., Jacobs D., Quality of Korotkoff sounds: bell vs diaphragm, cubital fossa vs brachial artery, Prev. Med, 12, pp. 715-9, (1983)
  • [26] Mauro A.M.P., Effects of the bell versus diaphragm on indirect blood pressure measurement, Heart Lung, 17, pp. 489-94, (1988)
  • [27] Cushman W.C., Cooper K.M., Home R.A., Meydrech E.F., Effect of back support and stethoscope head on seated blood pressure determinations, Am J Hypertens, 3, pp. 240-1, (1990)
  • [28] Zachariah P.K., Sheps S.G., Moore A.G., Office blood pressures in supine, sitting, and standing positions: correlation with ambulatory blood pressures, Int J Cardiol, 28, pp. 353-60, (1990)
  • [29] Pickering T.G., Posture and the measurement of blood pressure [editorial), Int J Cardiol, 29, pp. 109-11, (1990)
  • [30] Webster J., Newnham D., Petrie J.C., Lovell H.G., Influence of arm position on measurement of blood pressure, BMJ, 288, pp. 1574-5, (1984)