STABILITY OF SERUM PROSTATE-SPECIFIC ANTIGEN DETERMINATION ACROSS LABORATORY, ASSAY, AND STORAGE TIME

被引:25
作者
JACOBSEN, SJ
KLEE, GG
LILJA, H
WRIGHT, GL
OESTERLING, JE
机构
[1] MAYO CLIN & MAYO FDN,CLIN EPIDEMIOL SECT,ROCHESTER,MN 55905
[2] MAYO CLIN & MAYO FDN,DEPT LAB MED & PATHOL,ROCHESTER,MN 55905
[3] MAYO CLIN & MAYO FDN,DEPT UROL,ROCHESTER,MN 55905
[4] MAYO CLIN & MAYO FDN,DIV METAB & HEMATOL BIOCHEM,ROCHESTER,MN 55905
[5] LUND UNIV,MALMO GEN HOSP,DEPT CLIN CHEM,S-21401 MALMO,SWEDEN
[6] EASTERN VIRGINIA MED SCH,DEPT MICROBIOL & IMMUNOL,NORFOLK,VA 23501
[7] EASTERN VIRGINIA MED SCH,CTR UROL ONCOL,NORFOLK,VA 23501
关键词
D O I
10.1016/S0090-4295(99)80014-4
中图分类号
R5 [内科学]; R69 [泌尿科学(泌尿生殖系疾病)];
学科分类号
1002 ; 100201 ;
摘要
Objectives. To understand the comparability of serum prostate-specific antigen (PSA) determinations across assays and storage time. Methods. Serum PSA levels were determined for men aged 40 to 79 years from the clinical subset of the Olmsted County Study of Urinary Symptoms and Health Status Among Men on fresh samples and after a median of 32 months on banked samples, frozen at -70 degrees C. Baseline serum PSA levels were determined by Tandem-R PSA assay. Follow-up levels on the banked samples were determined by the IMx PSA assay and a repeat Tandem-R PSA assay in a different laboratory and by an immunofluorometric PSA assay at another site. Results. The median serum PSA level determined by Tandem-R assay at baseline was 1.0 ng/ml (25th percentile, 0.6; 75th percentile, 1.7). The distributions of determination made by follow-up Tandem-R, IMx, and immunofluorometric analyses were essentially identical. Overall, the assays were highly correlated. The correlations between the baseline serum PSA determination and repeated Tandem-R, IMx, and immunofluorometric determinations were 0.96, 0.96, and 0.97, respectively (all P <0.001). The median duration of frozen storage was 32 months (range, 26 to 39 months), and the correlations between baseline and follow-up determinations did not change when stratified by duration of storage. Conclusions. These data provide important reassurance about the use of serum PSA determinations obtained by different assays, in different laboratories, and in properly stored samples across time.
引用
收藏
页码:447 / 453
页数:7
相关论文
共 37 条
[1]   MEASUREMENT IN MEDICINE - THE ANALYSIS OF METHOD COMPARISON STUDIES [J].
ALTMAN, DG ;
BLAND, JM .
JOURNAL OF THE ROYAL STATISTICAL SOCIETY SERIES D-THE STATISTICIAN, 1983, 32 (03) :307-317
[2]   STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT [J].
BLAND, JM ;
ALTMAN, DG .
LANCET, 1986, 1 (8476) :307-310
[3]  
BRAWER M K, 1989, Journal of Endourology, V3, P227, DOI 10.1089/end.1989.3.227
[4]   SCREENING FOR PROSTATIC-CARCINOMA WITH PROSTATE-SPECIFIC ANTIGEN - RESULTS OF THE 2ND-YEAR [J].
BRAWER, MK ;
BEATIE, J ;
WENER, MH ;
VESSELLA, RL ;
PRESTON, SD ;
LANGE, PH .
JOURNAL OF UROLOGY, 1993, 150 (01) :106-109
[5]   LONGITUDINAL EVALUATION OF PROSTATE-SPECIFIC ANTIGEN LEVELS IN MEN WITH AND WITHOUT PROSTATE DISEASE [J].
CARTER, HB ;
PEARSON, JD ;
METTER, J ;
BRANT, LJ ;
CHAN, DW ;
ANDRES, R ;
FOZARD, JL ;
WALSH, PC .
JAMA-JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 1992, 267 (16) :2215-2220
[6]   DETECTION OF ORGAN-CONFINED PROSTATE-CANCER IS INCREASED THROUGH PROSTATE-SPECIFIC ANTIGEN-BASED SCREENING [J].
CATALONA, WJ ;
SMITH, DS ;
RATLIFF, TL ;
BASLER, JW .
JAMA-JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 1993, 270 (08) :948-954
[7]  
CATALONA WJ, 1994, UROLOGY, V42, P113
[8]  
CHODAK GW, 1994, UROLOGY, V42, P116
[9]   THE PREVALENCE OF PROSTATISM - A POPULATION-BASED SURVEY OF URINARY SYMPTOMS [J].
CHUTE, CG ;
PANSER, LA ;
GIRMAN, CJ ;
OESTERLING, JE ;
GUESS, HA ;
JACOBSEN, SJ ;
LIEBER, MM .
JOURNAL OF UROLOGY, 1993, 150 (01) :85-89
[10]   RELATIONSHIP BETWEEN PROSTATE-SPECIFIC ANTIGEN, PROSTATE VOLUME AND AGE IN THE BENIGN PROSTATE [J].
COLLINS, GN ;
LEE, RJ ;
MCKELVIE, GB ;
ROGERS, ACN ;
HEHIR, M .
BRITISH JOURNAL OF UROLOGY, 1993, 71 (04) :445-450