STABILITY OF SERUM PROSTATE-SPECIFIC ANTIGEN DETERMINATION ACROSS LABORATORY, ASSAY, AND STORAGE TIME

被引:25
作者
JACOBSEN, SJ
KLEE, GG
LILJA, H
WRIGHT, GL
OESTERLING, JE
机构
[1] MAYO CLIN & MAYO FDN,CLIN EPIDEMIOL SECT,ROCHESTER,MN 55905
[2] MAYO CLIN & MAYO FDN,DEPT LAB MED & PATHOL,ROCHESTER,MN 55905
[3] MAYO CLIN & MAYO FDN,DEPT UROL,ROCHESTER,MN 55905
[4] MAYO CLIN & MAYO FDN,DIV METAB & HEMATOL BIOCHEM,ROCHESTER,MN 55905
[5] LUND UNIV,MALMO GEN HOSP,DEPT CLIN CHEM,S-21401 MALMO,SWEDEN
[6] EASTERN VIRGINIA MED SCH,DEPT MICROBIOL & IMMUNOL,NORFOLK,VA 23501
[7] EASTERN VIRGINIA MED SCH,CTR UROL ONCOL,NORFOLK,VA 23501
关键词
D O I
10.1016/S0090-4295(99)80014-4
中图分类号
R5 [内科学]; R69 [泌尿科学(泌尿生殖系疾病)];
学科分类号
1002 ; 100201 ;
摘要
Objectives. To understand the comparability of serum prostate-specific antigen (PSA) determinations across assays and storage time. Methods. Serum PSA levels were determined for men aged 40 to 79 years from the clinical subset of the Olmsted County Study of Urinary Symptoms and Health Status Among Men on fresh samples and after a median of 32 months on banked samples, frozen at -70 degrees C. Baseline serum PSA levels were determined by Tandem-R PSA assay. Follow-up levels on the banked samples were determined by the IMx PSA assay and a repeat Tandem-R PSA assay in a different laboratory and by an immunofluorometric PSA assay at another site. Results. The median serum PSA level determined by Tandem-R assay at baseline was 1.0 ng/ml (25th percentile, 0.6; 75th percentile, 1.7). The distributions of determination made by follow-up Tandem-R, IMx, and immunofluorometric analyses were essentially identical. Overall, the assays were highly correlated. The correlations between the baseline serum PSA determination and repeated Tandem-R, IMx, and immunofluorometric determinations were 0.96, 0.96, and 0.97, respectively (all P <0.001). The median duration of frozen storage was 32 months (range, 26 to 39 months), and the correlations between baseline and follow-up determinations did not change when stratified by duration of storage. Conclusions. These data provide important reassurance about the use of serum PSA determinations obtained by different assays, in different laboratories, and in properly stored samples across time.
引用
收藏
页码:447 / 453
页数:7
相关论文
共 37 条
[11]   PROSTATE-CANCER DETECTION IN A CLINICAL UROLOGICAL PRACTICE BY ULTRASONOGRAPHY, DIGITAL RECTAL EXAMINATION AND PROSTATE SPECIFIC ANTIGEN [J].
COONER, WH ;
MOSLEY, BR ;
RUTHERFORD, CL ;
BEARD, JH ;
POND, HS ;
TERRY, WJ ;
IGEL, TC ;
KIDD, DD .
JOURNAL OF UROLOGY, 1990, 143 (06) :1146-1154
[12]  
DNISTRIAN AM, 1992, CLIN CHEM, V38, P2140
[13]  
Ellis William J., 1993, P276
[14]  
FIORE M, 1988, CLIN CHEM, V34, P1726
[15]  
FLEISS JL, 1986, DESIGN ANAL CLIN EXP, P233
[16]  
Jacobsen S J, 1993, Arch Fam Med, V2, P729, DOI 10.1001/archfami.2.7.729
[17]   MEASUREMENT OF SERUM PROSTATE-SPECIFIC ANTIGEN USING IMX PROSTATE-SPECIFIC ANTIGEN-ASSAY [J].
KLEE, GG ;
DODGE, LA ;
ZINCKE, H ;
OESTERLING, JE .
JOURNAL OF UROLOGY, 1994, 151 (01) :94-98
[18]  
KURIYAMA M, 1992, JPN J CLIN ONCOL, V22, P393
[19]   THE PATIENT RECORD IN EPIDEMIOLOGY [J].
KURLAND, LT ;
MOLGAARD, CA .
SCIENTIFIC AMERICAN, 1981, 245 (04) :54-63
[20]   PROSTATIC SPECIFIC ANTIGEN AS AN INDICATOR OF RESPONSE TO RADIOTHERAPY IN PROSTATE-CANCER [J].
LANDMANN, C ;
HUNIG, R .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1989, 17 (05) :1073-1076