RELEVANCE OF ENANTIOMERIC SEPARATIONS IN ENVIRONMENTAL SCIENCE

被引:60
作者
ARMSTRONG, DW
REID, GL
HILTON, ML
CHANG, CD
机构
[1] Department of Chemistry, University of Missouri-Rolla, Rolla
关键词
D O I
10.1016/0269-7491(93)90177-P
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
A significant number of all organic chemicals that are released into the enviromnent are racemic mixtures. Most environmental regulations and scientific environmental studies treat racemic mixtures as though they were single, pure compounds. This can lead to incorrect toxicological, distribution, degradation and other data. A series of new enantioselective chromatographic techniques have been developed that allow the facile separation and quantitation of chiral compounds of environmental importance. Nineteen racemic compounds that have been or currently are being released to the environment are resolved. These include: rodenticides-Warfarin, Coumachlor and Coumafuryl; insecticides-Crufomate, Bulan, Fonofos, Mitotane; insect repellent-Ethohexadiol, herbicides and fungicides-Ancymidol, Silvex, Napropamide, phenyl mercuric lactate, 2-[3-chlorophenoxy]propionamide, and 2-chloropropionic acid; and halocarbons-1,2-dichloropropane, 2-bromo-1-chloropropane, 1,2-dibromo-3-chloropropane, 2,3-dichlorobutane and alpha-1,2,3,4,5,6-hexachlorocyclohexane. Several examples are given to illustrate the importance of enantioselective measurements of these and other compounds. Choosing the proper chromatographic technique and chiral stationary phase based on analyte structure is also discussed.
引用
收藏
页码:51 / 58
页数:8
相关论文
共 22 条
[1]  
Ariens EJ, 1989, CHIRAL SEPARATIONS H, P31
[2]  
ARMSTRONG DW, 1991, LC GC-MAG SEP SCI, V9, P646
[3]   RELEVANCE OF ENANTIOMERIC SEPARATIONS IN FOOD AND BEVERAGE ANALYSES [J].
ARMSTRONG, DW ;
CHANG, CD ;
LI, WY .
JOURNAL OF AGRICULTURAL AND FOOD CHEMISTRY, 1990, 38 (08) :1674-1677
[4]  
ARMSTRONG DW, 1988, CRIT REV ANAL CHEM, V19, P175
[5]   POLAR-LIQUID, DERIVATIZED CYCLODEXTRIN STATIONARY PHASES FOR THE CAPILLARY GAS-CHROMATOGRAPHY SEPARATION OF ENANTIOMERS [J].
ARMSTRONG, DW ;
LI, WY ;
CHANG, CD ;
PITHA, J .
ANALYTICAL CHEMISTRY, 1990, 62 (09) :914-923
[6]   A STATIC COATING PROCEDURE FOR GLASS CAPILLARY COLUMNS [J].
BOUCHE, J ;
VERZELE, M .
JOURNAL OF GAS CHROMATOGRAPHY, 1968, 6 (10) :501-&
[7]   THE MEASUREMENT OF WARFARIN ENANTIOMERS IN SERUM USING COUPLED ACHIRAL CHIRAL, HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY (HPLC) [J].
CHU, YQ ;
WAINER, IW .
PHARMACEUTICAL RESEARCH, 1988, 5 (10) :680-683
[8]   THE FDA PERSPECTIVE ON THE DEVELOPMENT OF STEREOISOMERS [J].
DECAMP, WH .
CHIRALITY, 1989, 1 (01) :2-6
[9]   STEREOSELECTIVE DISPOSITION OF MEXILETINE IN MAN [J].
GRECHBELANGER, O ;
TURGEON, J ;
GILBERT, M .
BRITISH JOURNAL OF CLINICAL PHARMACOLOGY, 1986, 21 (05) :481-487
[10]   GAS-CHROMATOGRAPHIC SEPARATION OF THE ENANTIOMERS OF ORGANIC MARINE POLLUTANTS .2. ENANTIOSELECTIVE METABOLISM OF (+/-)-ALPHA-1,2,3,4,5,6-HEXACHLOROCYCLOHEXANE IN ORGANS OF THE EIDER DUCK [J].
KALLENBORN, R ;
HUHNERFUSS, H ;
KONIG, WA .
ANGEWANDTE CHEMIE-INTERNATIONAL EDITION IN ENGLISH, 1991, 30 (03) :320-321