IN-VIVO COMPARISON OF 3D ULTRASONOGRAPHY AND MAGNETIC-RESONANCE-IMAGING IN VOLUME ESTIMATION OF HUMAN KIDNEYS

被引:89
作者
GILJA, OH
SMIEVOLL, AI
THUNE, N
MATRE, K
HAUSKEN, T
ODEGAARD, S
BERSTAD, A
机构
[1] UNIV BERGEN, HAUKELAND HOSP, DEPT RADIOL, N-5021 BERGEN, NORWAY
[2] CHRISTIAN MICHELSEN RES, BERGEN, NORWAY
关键词
COMPUTER GRAPHICS; KIDNEY; MAGNETIC RESONANCE IMAGING (MRI); 3-DIMENSIONAL RECONSTRUCTION; 3D IMAGING; 3D ULTRASOUND; VOLUME MEASUREMENTS; ULTRASONIC IMAGING; ULTRASONOGRAPHY; Z;
D O I
10.1016/0301-5629(94)00082-4
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
The objective of this study was to evaluate the accuracy of a three-dimensional ultrasound system (3D-US) compared with Magnetic Resonance Imaging (MRI) in volume estimation of human kidneys in vivo. Twenty healthy volunteers were scanned fasting in supine position with MRI and with a 3D-US. An ultrasound sector scanner with a mechanical transducer coupled to a tilting motor provided images of multiple sections of kidneys. A 3.25-MHz transducer was tilted through 88 degrees yielding 81 frames, and volume estimation was performed on a Unix workstation after manual contour indication. Data acquisition with MRI was performed by using a 1-T magnet. Eighteen included kidneys [mean +/- standard deviation (SD)] measured 155.7 +/- 26.4 mL (range 110.0-205.0 mL) by 3D ultrasound and 171.8 +/- 24.6 mL (range 127.5-211.0 mL) by MRI, yielding a good correlation (r = 0.82, p < 0.001) between the two methods. The mean difference was -16.1 +/- 15.6 mL (SD) and the limits of agreement were -49.0 mL; 16.7 mL. We conclude that this 3D-US is accurate in volume estimation of human kidneys in vivo.
引用
收藏
页码:25 / 32
页数:8
相关论文
共 27 条
[1]   CHANGES IN TRANSPLANTED KIDNEY VOLUME MEASURED BY ULTRASOUND [J].
ABSY, M ;
METREWELI, C ;
MATTHEWS, C ;
ALKHADER, A .
BRITISH JOURNAL OF RADIOLOGY, 1987, 60 (714) :525-529
[2]  
[Anonymous], 1991, GRAPHICS GEMS
[3]   EVALUATION OF A 3-DIMENSIONAL RECONSTRUCTION TO COMPUTE LEFT-VENTRICULAR VOLUME AND MASS [J].
ARIET, M ;
GEISER, EA ;
LUPKIEWICZ, SM ;
CONETTA, DA ;
CONTI, CR .
AMERICAN JOURNAL OF CARDIOLOGY, 1984, 54 (03) :415-420
[4]   VOLUME MEASUREMENT BY ULTRASONIC TRANSVERSE OR SAGITTAL CROSS-SECTIONAL SCANNING [J].
BASSET, O ;
GIMENEZ, G ;
MESTAS, JL ;
CATHIGNOL, D ;
DEVONEC, M .
ULTRASOUND IN MEDICINE AND BIOLOGY, 1991, 17 (03) :291-296
[5]   STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT [J].
BLAND, JM ;
ALTMAN, DG .
LANCET, 1986, 1 (8476) :307-310
[6]   INVITRO EVALUATION OF AN ULTRASONIC 3-DIMENSIONAL IMAGING AND VOLUME SYSTEM [J].
BRINKLEY, JF ;
MURAMATSU, SK ;
MCCALLUM, WD ;
POPP, RL .
ULTRASONIC IMAGING, 1982, 4 (02) :126-139
[7]   ENHANCED COLOR FLOW IMAGING OF BREAST-CANCER VASCULATURE - CONTINUOUS WAVE DOPPLER AND 3-DIMENSIONAL DISPLAY [J].
CARSON, PL ;
ADLER, DD ;
FOWLKES, JB ;
HARNIST, K ;
RUBIN, J .
JOURNAL OF ULTRASOUND IN MEDICINE, 1992, 11 (08) :377-385
[8]   3-DIMENSIONAL (3D) ULTRASOUND IMAGING OF THE GALLBLADDER AND DILATED BILIARY TREE - RECONSTRUCTION FROM REAL-TIME B-SCANS [J].
FINE, D ;
PERRING, S ;
HERBETKO, J ;
HACKING, CN ;
FLEMING, JS ;
DEWBURY, KC .
BRITISH JOURNAL OF RADIOLOGY, 1991, 64 (767) :1056-1057
[9]   3-DIMENSIONAL IMAGING [J].
FISHMAN, EK ;
MAGID, D ;
NEY, DR ;
CHANEY, EL ;
PIZER, SM ;
ROSENMAN, JG ;
LEVIN, DN ;
VANNIER, MW ;
KUHLMAN, JE ;
ROBERTSON, DD .
RADIOLOGY, 1991, 181 (02) :321-337
[10]  
GANAPATHY S, 1982, COMPUT GRAPHICS ACM, V16, P69, DOI DOI 10.1145/965145.801264