摘要
The purpose of the study was to implement and assess a fast-screening, three-dimensional Fourier transformation (3DFT) MR sequence for the cervical spine. This sequence maintains adequate signal-to-noise and image contrast similar to gradient-recalled echo two-dimensional Fourier transformation (2DFT) imaging. Thirty patients with radiculopathy were examined with 3DFT gradient-recalled echo imaging. The data set consisted of 60 contiguous 1.5- to 2.0-mm-thick axial slices with a total coverage of 9 to 12 cm. In 10 patients, comparison was made with 4-mm-thick axial T1-weighted spin-echo 2DFT or gradient-recalled echo 2DFT studies. With the use of a volume acquisition, adequate signal-to-noise and image contrast similar to T2*-weighted gradient-recalled echo 2DFT acquisitions were obtainable. Coverage was improved despite the use of thinner sections without interslice gap. Thin-section 3DFT provided superior detail of acquired foraminal and spinal canal stenosis and disk morphology. Limitations included increased sensitivity to patient motion and 'wraparound' artifact in the slice-select direction. Overall, diagnostic confidence was improved with 3DFT owing to the reduction of partial volume artifact. We have adopted this technique as the primary screening method for diagnosing cervical radiculopathy.
引用
收藏
页码:375 / 383
页数:9
相关论文
共 45 条
[1]   MR SEQUENCE PARAMETER OPTIMIZATION - AN ALGORITHMIC APPROACH [J].
BRADLEY, WG ;
TSURUDA, JS .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1987, 149 (04) :815-823
[2]  
BREGER RK, 1988, AM J NEURORADIOL, V9, P825
[3]  
BROWN BM, 1988, AM J NEURORADIOL, V9, P859
[4]   CONTRAST IN RAPID MR IMAGING - T1-WEIGHTED AND T2-WEIGHTED IMAGING [J].
BUXTON, RB ;
EDELMAN, RR ;
ROSEN, BR ;
WISMER, GL ;
BRADY, TJ .
JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 1987, 11 (01) :7-16
[5]   SIGNAL-TO-NOISE RATIO AND SECTION THICKNESS IN TWO-DIMENSIONAL VERSUS 3-DIMENSIONAL FOURIER-TRANSFORM MR IMAGING [J].
CARLSON, J ;
CROOKS, L ;
ORTENDAHL, D ;
KRAMER, DM ;
KAUFMAN, L .
RADIOLOGY, 1988, 166 (01) :266-270
[6]  
CZERVIONKE LF, 1988, AM J NEURORADIOL, V9, P815
[7]  
CZERVIONKE LF, 1988, AM J NEURORADIOL, V9, P1149
[8]   CERVICAL NEURAL FORAMINA - CORRELATIVE ANATOMIC AND MR IMAGING STUDY [J].
CZERVIONKE, LF ;
DANIELS, DL ;
HO, PSP ;
YU, SW ;
PECH, P ;
STRANDT, J ;
WILLIAMS, AL ;
HAUGHTON, VM .
RADIOLOGY, 1988, 169 (03) :753-759
[9]  
EHMAN RL, 1987, P ANN M SOC MAGN RES, P56
[10]   CERVICAL-SPINE MR IMAGING - GENERATING HIGH-SIGNAL CSF IN SAGITTAL AND AXIAL IMAGES [J].
ENZMANN, DR ;
RUBIN, JB ;
WRIGHT, A .
RADIOLOGY, 1987, 163 (01) :233-238