3-DIMENSIONAL GRADIENT-RECALLED MR IMAGING AS A SCREENING TOOL FOR THE DIAGNOSIS OF CERVICAL RADICULOPATHY

被引:9
作者
TSURUDA, JS [1 ]
NORMAN, D [1 ]
DILLON, W [1 ]
NEWTON, TH [1 ]
MILLS, DG [1 ]
机构
[1] DIAGNOST IMAGING CONSULTANTS INC,CHATTANOOGA,TN 37404
关键词
D O I
10.2214/ajr.154.2.2153331
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The purpose of the study was to implement and assess a fast-screening, three-dimensional Fourier transformation (3DFT) MR sequence for the cervical spine. This sequence maintains adequate signal-to-noise and image contrast similar to gradient-recalled echo two-dimensional Fourier transformation (2DFT) imaging. Thirty patients with radiculopathy were examined with 3DFT gradient-recalled echo imaging. The data set consisted of 60 contiguous 1.5- to 2.0-mm-thick axial slices with a total coverage of 9 to 12 cm. In 10 patients, comparison was made with 4-mm-thick axial T1-weighted spin-echo 2DFT or gradient-recalled echo 2DFT studies. With the use of a volume acquisition, adequate signal-to-noise and image contrast similar to T2*-weighted gradient-recalled echo 2DFT acquisitions were obtainable. Coverage was improved despite the use of thinner sections without interslice gap. Thin-section 3DFT provided superior detail of acquired foraminal and spinal canal stenosis and disk morphology. Limitations included increased sensitivity to patient motion and 'wraparound' artifact in the slice-select direction. Overall, diagnostic confidence was improved with 3DFT owing to the reduction of partial volume artifact. We have adopted this technique as the primary screening method for diagnosing cervical radiculopathy.
引用
收藏
页码:375 / 383
页数:9
相关论文
共 45 条
[31]  
Roemer P.B., 1986, P 5 ANN M ISMRM MONT, P1067
[32]   SPINAL MR IMAGING - MULTIPLANAR REPRESENTATION FROM A SINGLE HIGH-RESOLUTION 3D ACQUISITION [J].
SHERRY, CS ;
HARMS, SE ;
MCCROSKEY, WK .
JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 1987, 11 (05) :859-862
[33]   MR IMAGING OF THE KNEE - PRELIMINARY-RESULTS WITH A 3DFT GRASS PULSE SEQUENCE [J].
SPRITZER, CE ;
VOGLER, JB ;
MARTINEZ, S ;
GARRETT, WE ;
JOHNSON, GA ;
MCNAMARA, MJ ;
LOHNES, J ;
HERFKENS, RJ .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1988, 150 (03) :597-603
[34]   FAST 3-DIMENSIONAL MR IMAGING OF THE KNEE - COMPARISON WITH ARTHROSCOPY [J].
TYRRELL, RL ;
GLUCKERT, K ;
PATHRIA, M ;
MODIC, MT .
RADIOLOGY, 1988, 166 (03) :865-872
[35]  
WHERLI FW, 1986, ADV MR IMAGING TECHN, P8
[36]  
WHERLI FW, 1986, ADV MR IMAGING TECHN, P4
[37]   TEMPOROMANDIBULAR-JOINT - MULTISLAB, 3-DIMENSIONAL FOURIER TRANSFORMATION MR IMAGING [J].
WILK, RM ;
HARMS, SE .
RADIOLOGY, 1988, 167 (03) :861-863
[38]   CHARACTERISTICS OF PARTIAL FLIP ANGLE AND GRADIENT REVERSAL MR IMAGING [J].
WINKLER, ML ;
ORTENDAHL, DA ;
MILLS, TC ;
CROOKS, LE ;
SHELDON, PE ;
KAUFMAN, L ;
KRAMER, DM .
RADIOLOGY, 1988, 166 (01) :17-26
[39]   OPTIMIZATION OF SPOILER GRADIENTS IN FLASH MRI [J].
WOOD, ML ;
SILVER, M ;
RUNGE, VM .
MAGNETIC RESONANCE IMAGING, 1987, 5 (06) :455-463
[40]   OVERCOMING MOTION IN ABDOMINAL MR IMAGING [J].
WOOD, ML ;
RUNGE, VM ;
HENKELMAN, RM .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1988, 150 (03) :513-522