An ambient air monitoring program to characterize airborne emissions from the Exxon petroleum refinery at Benicia, California was conducted during September 8–22, 1975. Ground level sampling facilities and an instrumented aircraft provided an integrated, three-dimensional monitoring network. Measurements made during the study included ozone, oxides of nitrogen, methane, carbon monoxide, individual C2-C6hydrocarbons, halocarbons, condensation nuclei, visual distance and various meteorological parameters. The study focused on three major areas: (1) the characterization of gaseous components within the refinery effluent, especially non-methane hydrocarbons and ozone, (2) natural sunlight bag irradiation experiments to determine the ozone forming potential of refinery emissions, and (3) an investigation of changes in plume chemistry as refinery emissions were transported downwind. © Taylor & Francis Group, LLC.