SPECTRAL LINESHAPE DETERMINATION BY SELF-DECONVOLUTION

被引:35
作者
MAUDSLEY, AA
机构
[1] Department of Radiology, University of California San Francisco, San Francisco, CA 94121
来源
JOURNAL OF MAGNETIC RESONANCE SERIES B | 1995年 / 106卷 / 01期
关键词
D O I
10.1006/jmrb.1995.1007
中图分类号
O64 [物理化学(理论化学)、化学物理学]; O56 [分子物理学、原子物理学];
学科分类号
070203 ; 070304 ; 081704 ; 1406 ;
摘要
A data-processing method is described for the determination of spectral lineshapes using deconvolution of the data with an initial estimate of the same spectrum, referred to as self-deconvolution. The method is demonstrated using computer-simulation studies and experimental data, and is shown to accurately determine amplitude and phase lineshape distortions which may be caused by field inhomogeneity and gradient eddy-current effects. The results indicate that the method is robust in the presence of noise and errors in the initial spectral estimate. Once the spectral lineshape is determined it can be incorporated into a parametric spectral-analysis procedure, thereby reducing the number of parameters to be determined and improving the accuracy of the fit. A proposed application of the method is for spatially resolved in vivo NMR studies where local susceptibility effects and gradient eddy-current effects cause significant deviation of the spectral lineshape from a Lorentzian lineshape. (C) 1995 Academic Press, Inc.
引用
收藏
页码:47 / 57
页数:11
相关论文
共 24 条
[1]  
Bracewell R. N., 1986, FOURIER TRANSFORM IT
[2]  
DAVIES SJ, 1988, J MAGN RESON, V74, P476
[3]   REDUCED LIPID CONTAMINATION IN IN-VIVO H-1 MRSI USING TIME-DOMAIN FITTING AND NEURAL-NETWORK CLASSIFICATION [J].
DEBEER, R ;
MICHELS, F ;
VANORMONDT, D ;
VANTONGEREN, BPO ;
LUYTEN, PR ;
VANVROONHOVEN, H .
MAGNETIC RESONANCE IMAGING, 1993, 11 (07) :1019-1026
[4]  
DEGRAAF AA, 1990, MAGN RESON MED, V13
[5]  
DENHOLLANDER JA, 1991, P SOC MAGNETIC RESON, P472
[6]   3-DIMENSIONAL H-1 SPECTROSCOPIC IMAGING OF CEREBRAL METABOLITES IN THE RAT USING SURFACE COILS [J].
FERNANDEZ, EJ ;
MAUDSLEY, AA ;
HIGUCHI, T ;
WEINER, MW .
MAGNETIC RESONANCE IMAGING, 1992, 10 (06) :965-974
[7]   REFERENCE DECONVOLUTION - ELIMINATION OF DISTORTIONS ARISING FROM REFERENCE LINE TRUNCATION [J].
GIBBS, A ;
MORRIS, GA .
JOURNAL OF MAGNETIC RESONANCE, 1991, 91 (01) :77-83
[8]   SELF-CORRECTION OF PROTON SPECTROSCOPIC IMAGES FOR GRADIENT EDDY-CURRENT DISTORTIONS AND STATIC-FIELD INHOMOGENEITIES [J].
JOHNSON, G ;
JUNG, KJ ;
WU, EX ;
HILAL, SK .
MAGNETIC RESONANCE IN MEDICINE, 1993, 30 (02) :255-261
[9]   AN ALGORITHM FOR LEAST-SQUARES ESTIMATION OF NONLINEAR PARAMETERS [J].
MARQUARDT, DW .
JOURNAL OF THE SOCIETY FOR INDUSTRIAL AND APPLIED MATHEMATICS, 1963, 11 (02) :431-441
[10]   FIELD INHOMOGENEITY CORRECTION AND DATA-PROCESSING FOR SPECTROSCOPIC IMAGING [J].
MAUDSLEY, AA ;
HILAL, SK .
MAGNETIC RESONANCE IN MEDICINE, 1985, 2 (03) :218-233