DETERMINATION OF NETILMICIN IN SERUM BY THIN-LAYER DENSITOMETRY AND FLUORESCENCE POLARIZATION IMMUNOASSAY

被引:4
作者
KUNZ, FR
JORK, H
KELLER, HE
机构
[1] UNIV SAARLAND,FACHBEREICH PHARM & BIOL CHEM,BAU 12,W-6600 SAARBRUCKEN,GERMANY
[2] DEGUSSA,FACHBEREICH FORSCH ORGAN & BIOL CHEM,W-6450 HANAU,GERMANY
[3] UNIV HOMBURG,MED KLIN,ZENTR LAB,W-6650 HOMBURG,GERMANY
来源
FRESENIUS JOURNAL OF ANALYTICAL CHEMISTRY | 1993年 / 346卷 / 6-9期
关键词
D O I
10.1007/BF00321303
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A newly developed thin-layer chromatographic method (TLC) for the quantitative determination of netilmicin in serum is described and compared with fluorescence polarization immunoassay (FPIA). The TLC procedure involves solid-phase extraction of the aminoglycoside from serum and chromatography on reversed-phase thin layer. Post-chromatographic derivatization is carried out using 2,2-diphenyl-1-oxa-3-oxonia-2-boratanaphthalene (DOOB) as fluorescence reagent. The calibration curve for netilmicin in serum is linear in the range 1.0-5.0 mug/ml and the detection limit is about 0.2 mug/ml (correlation coefficient r = 0.9963, mean coefficient of variation V(xo) = +/- 5.3 %). A total of 25 serum samples from patients treated with netilmicin was measured by TLC and the results were compared with those of FPIA (Abbott TDx). There is no statistically significant difference between the two procedures (y = -0.35 + 1.094 . x, Passing/Bablok). Thus the TLC-procedure is an altemative for the determination of netilmicin in serum, that possesses the necessary sensitivity of other comparable methods.
引用
收藏
页码:847 / 851
页数:5
相关论文
共 46 条
[11]   AN AUTOMATED HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHIC METHOD FOR THE DETERMINATION OF AMINOGLYCOSIDES IN SERUM USING PRE-COLUMN SAMPLE CLEANUP AND DERIVATIZATION [J].
ESSERS, L .
JOURNAL OF CHROMATOGRAPHY, 1984, 305 (02) :345-352
[12]  
FABER DB, 1982, CURRENT CHEMOTHERAPY, V2, P800
[13]  
HELWIG H, 1983, DTSCH APOTH ZTG, V123, P139
[14]   THIN-LAYER CHROMATOGRAPHIC-SEPARATION AND FLUORIMETRIC DETERMINATION OF PRIMARY AMINES AFTER DERIVATIZATION TO SALICYLALDEHYDEAZOMETHINE-DIPHENYLBORON CHELATES [J].
HOHAUS, E .
FRESENIUS ZEITSCHRIFT FUR ANALYTISCHE CHEMIE, 1982, 310 (1-2) :70-76
[15]  
HOHAUS E, 1984, BUNSEKI KAGAKU, V33, pE55
[16]   SERUM ASSAYS OF NETILMICIN BY ENZYME MULTIPLIED IMMUNOASSAY TECHNIQUE AND BIOASSAY - A COMPARATIVE-STUDY [J].
JANSSON, L ;
HENNING, C .
ANTIMICROBIAL AGENTS AND CHEMOTHERAPY, 1982, 22 (06) :1058-1060
[17]  
JOHNSON C, 1982, ROAYL SOC MED INT C, V50, P47
[18]   LONG-TERM ACCURACY OF FLUORESCENCE POLARIZATION IMMUNOASSAYS FOR GENTAMICIN, TOBRAMYCIN, NETILMICIN AND VANCOMYCIN [J].
JOOS, B ;
LUTHY, R ;
BLASER, J .
JOURNAL OF ANTIMICROBIAL CHEMOTHERAPY, 1989, 24 (05) :797-803
[19]   SOME CAUSES FOR VARIATION IN AMINOGLYCOSIDE PLATE ASSAYS [J].
KAHLMETER, G .
JOURNAL OF ANTIMICROBIAL CHEMOTHERAPY, 1980, 6 (01) :43-52
[20]   DETERMINATION OF SISOMICIN, NETILMICIN, ASTROMICIN AND MICRONOMICIN IN SERUM BY HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY [J].
KAWAMOTO, T ;
MASHIMO, I ;
YAMAUCHI, S ;
WATANABE, M .
JOURNAL OF CHROMATOGRAPHY, 1984, 305 (02) :373-379