VALIDATION OF THE INVIVO MEASUREMENT OF ADIPOSE-TISSUE BY MAGNETIC-RESONANCE-IMAGING OF LEAN AND OBESE PIGS

被引:79
作者
FOWLER, PA
FULLER, MF
GLASBEY, CA
CAMERON, GG
FOSTER, MA
机构
[1] ROWETT RES INST,BUCKSBURN AB2 9SB,ABERDEEN,SCOTLAND
[2] SCOTTISH AGR STAT SERV,EDINBURGH,SCOTLAND
[3] UNIV ABERDEEN,DEPT BIOMED PHYS & BIOENGN,ABERDEEN AB9 2ZD,SCOTLAND
关键词
MAGNETIC RESONANCE IMAGING; ADIPOSE TISSUE; LIPID; VALIDATION; BODY COMPOSITION;
D O I
10.1093/ajcn/56.1.7
中图分类号
R15 [营养卫生、食品卫生]; TS201 [基础科学];
学科分类号
100403 ;
摘要
In vivo quantification of adipose tissue with magnetic resonance imaging (MRI) was validated with pigs. Thirteen transaxial MRI sections were collected, at intervals proportional to body length, from each pig, which was then killed, frozen, and sliced at the locations of the MRI sections. Adipose-tissue quantities were determined by dissecting each slice, and lipid contents of the dissected slices and of the tissue segments between slices were measured. Compared with dissection, MRI underestimated abdominal percent adipose tissue and overestimated cervical percent adipose tissue by < 6%. When all 13 sections were used, MRI closely predicted percent lipid and dissected percent adipose tissue with small residual SDs (RSD = 1.9 and 2.1, respectively), which increased only slightly if two sections (4, upper thorax and 8, upper abdomen) were used (RSD = 2.3 and 2.6, respectively). In conclusion MRI accurately quantifies adipose tissue in vivo, matching values produced by dissection and chemical analysis.
引用
收藏
页码:7 / 13
页数:7
相关论文
共 22 条
[11]   SUB-CUTANEOUS FAT THICKNESS MEASURED BY MAGNETIC-RESONANCE IMAGING, ULTRASOUND, AND CALIPERS [J].
HAYES, PA ;
SOWOOD, PJ ;
BELYAVIN, A ;
COHEN, JB ;
SMITH, FW .
MEDICINE AND SCIENCE IN SPORTS AND EXERCISE, 1988, 20 (03) :303-309
[12]   GALACTOPOIETIC AND MAMMOGENIC EFFECTS OF LONG-TERM TREATMENT WITH BOVINE GROWTH-HORMONE AND THRICE DAILY MILKING IN GOATS [J].
KNIGHT, CH ;
FOWLER, PA ;
WILDE, CJ .
JOURNAL OF ENDOCRINOLOGY, 1990, 127 (01) :129-138
[13]  
KVIST H, 1988, INT J OBESITY, V12, P249
[14]   USE OF NMR FOR MEASUREMENT OF TOTAL-BODY WATER AND ESTIMATION OF BODY-FAT [J].
LEWIS, DS ;
ROLLWITZ, WL ;
BERTRAND, HA ;
MASORO, EJ .
JOURNAL OF APPLIED PHYSIOLOGY, 1986, 60 (03) :836-840
[15]   BODY-FAT IN LEAN AND OVERWEIGHT WOMEN ESTIMATED BY 6 METHODS [J].
MCNEILL, G ;
FOWLER, PA ;
MAUGHAN, RJ ;
MCGAW, BA ;
FULLER, MF ;
GVOZDANOVIC, D ;
GVOZDANOVIC, S .
BRITISH JOURNAL OF NUTRITION, 1991, 65 (02) :95-103
[16]   ENERGY-SOURCES IN FASTING GREY SEAL PUPS EVALUATED WITH COMPUTED-TOMOGRAPHY [J].
NORDOY, ES ;
BLIX, AS .
AMERICAN JOURNAL OF PHYSIOLOGY, 1985, 249 (04) :R471-R476
[17]  
ROSSNER S, 1990, INT J OBESITY, V14, P893
[18]   IMAGING TECHNIQUES FOR MEASURING ADIPOSE-TISSUE DISTRIBUTION - A COMPARISON BETWEEN COMPUTED-TOMOGRAPHY AND 1.5-T MAGNETIC-RESONANCE [J].
SEIDELL, JC ;
BAKKER, CJG ;
VANDERKOOY, K .
AMERICAN JOURNAL OF CLINICAL NUTRITION, 1990, 51 (06) :953-957
[19]  
STANDAL N, 1984, IN VIVO MEASUREMENT, P43
[20]   MEASUREMENT OF FAT DISTRIBUTION BY MAGNETIC-RESONANCE IMAGING [J].
STATEN, MA ;
TOTTY, WG ;
KOHRT, WM .
INVESTIGATIVE RADIOLOGY, 1989, 24 (05) :345-349