PLASTIC MEMBRANE AND COATED WIRE ION-SELECTIVE ELECTRODES FOR PROPYLHEXEDRINE

被引:10
作者
ZAREH, M [1 ]
ELSHEIKH, R [1 ]
ISSA, YM [1 ]
SHOUKRY, AF [1 ]
机构
[1] UNIV CAIRO,FAC SCI,DEPT CHEM,CAIRO,EGYPT
关键词
PROPYLHEXEDRINE ION-SELECTIVE ELECTRODE; POLY(VINYLCHLORIDE) MEMBRANE; ISOTHERMAL TEMPERATURE COEFFICIENT;
D O I
10.1080/00032719208020026
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Propylhexedrine (PX) ion selective electrode based on plasticized (PX)-tetraphenylboron with dioctylphthalate in poly(vinyl chloride) (PVC)-matrix. The electrode shows near Nernstian response over the concentration range 2.5 x 10(-5)-10(-1) solutions of the drug. The working pH-range of the electrode is 2.5-9.5 at 25-degrees-C. The electrode response can be considered Nernstian over the temperature range 25 - 60-degrees-C with isothermal temperature coefficient 0.00025 V/degrees-C. The selectivity coefficient of the electrode is calculated towards several inorganic cations, sugars, amines, amino acids and some other pharmaceutical preparations. Also, a coated wire ion-selective electrode based on the same ion pair was found to give a Nernstian response for a concentration range of 10(-4)-10(-2) M PXH+ solution. Propylhexedrine (2-cyclohexyl-N, 1-dimethyl-ethyl amine)(PX) is a volatile sympathomimetic amine with a local vasoconstrictor action, but when inhaled it has a little stimulating effect on the central nervous system. Many methods have been used for determination of PX depending mainly on extraction1,2, mass spectrometry3,4 and colorimetric method using tetrabromophenolphthalein5. Also, chromatographic methods were widely used for separation and determination of the drug. Among these methods are high performance chromatography6,7, adsorption chromatography8, thin-layer chromatography9,10 and gas chromatography11-13. Combined chromatographic techniques were applied depending on the use of more than one chromatographic technique like TLC-GLC-HPLC14, TLC-GLC15, TLC-GC16,17. No ion-selective electrode of any type has been ever reported for PX. In the present work, the construction and the behaviour of PX (I) ion-selective electrode is based on the PX-TPB lipophilic salt in plasticized PVC-matrix. This electrode offers an easy technique for the selective determination of PX.
引用
收藏
页码:663 / 680
页数:18
相关论文
共 22 条
[1]  
ALFES H, 1971, SPORTARZT SPORTMED, V22, P101
[2]  
ALFES H, 1971, SPORTARZT SPORTMED, V22, P104
[3]   ION-SELECTIVE ELECTRODE FOR THE DETERMINATION OF METOCLOPRAMIDE [J].
BADAWY, SS ;
SHOUKRY, AF ;
ISSA, YM .
ANALYST, 1986, 111 (12) :1363-1365
[4]   IDENTIFICATION AND CHEMICAL CLASSIFICATION OF DRUGS BASED ON RELATIVE RESPONSE OF A NITROGEN SELECTIVE DETECTOR AND A FLAME IONIZATION DETECTOR IN GAS-CHROMATOGRAPHIC ANALYSIS [J].
BAKER, JK .
ANALYTICAL CHEMISTRY, 1977, 49 (07) :906-908
[5]   IDENTIFICATION OF DRUGS BY HIGH-PRESSURE LIQUID-CHROMATOGRAPHY WITH DUAL WAVELENGTH ULTRAVIOLET DETECTION [J].
BAKER, JK ;
SKELTON, RE ;
MA, C .
JOURNAL OF CHROMATOGRAPHY, 1979, 168 (02) :417-427
[6]  
COSOFRET VV, 1986, ANALYST, V109, P1321
[7]   APPLICATION OF POLAR STATIONARY PHASES OV-225 AND OV-275 IN DETECTION OF DRUGS IN URINE SAMPLES [J].
DADISCH, GL ;
VYCUDILIK, W ;
MACHATA, G .
FORENSIC SCIENCE, 1977, 10 (03) :205-216
[8]   COMBINATION OF TLC, GLC (OV1 AND OV17) AND HPLC (RP18) FOR A RAPID DETECTION OF DRUGS AND RELATED-COMPOUNDS [J].
DALDRUP, T ;
SUSANTO, F ;
MICHALKE, P .
FRESENIUS ZEITSCHRIFT FUR ANALYTISCHE CHEMIE, 1981, 308 (05) :413-427
[9]   COMPARISON OF THE GC/MS ION TRAPPING TECHNIQUE WITH GC-FTIR FOR THE IDENTIFICATION OF STIMULANTS IN DRUG-TESTING [J].
DEJONG, EG ;
KEIZERS, S ;
MAES, RAA .
JOURNAL OF ANALYTICAL TOXICOLOGY, 1990, 14 (02) :127-131
[10]   WHY DO DOPING CONTROL LABS NEED A TANDEM MASS-SPECTROMETER [J].
DEJONG, EG ;
MAES, RAA ;
VANROSSUM, JM .
BIOMEDICAL AND ENVIRONMENTAL MASS SPECTROMETRY, 1988, 16 (1-12) :75-80