FERMENTATION MONITORING USING A GLUCOSE BIOSENSOR BASED ON AN ELECTROCATALYTICALLY BULK-MODIFIED EPOXY-GRAPHITE BIOCOMPOSITE INTEGRATED IN A FLOW SYSTEM

被引:15
作者
CESPEDES, F [1 ]
VALERO, F [1 ]
MARTINEZFABREGAS, E [1 ]
BARTROLI, J [1 ]
ALEGRET, S [1 ]
机构
[1] UNIV AUTONOMA BARCELONA,DEPT QUIM,UNITAT ENGN QUIM,E-08193 BARCELONA,SPAIN
关键词
GLUCOSE BIOSENSOR; GLUCOSE ANALYZER; FLOW INJECTION; BIOCOMPOSITE; GLUCOSE OXIDASE CONDUCTING COMPOSITE;
D O I
10.1039/an9952002255
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Glucose oxidase (GOD) and metals for the electrocatalytic oxidation of hydrogen peroxide were incorporated in the bulk of a graphite-epoxy composite. An amperometric glucose biosensor based on this biocomposite material made of graphite-epoxy-Au-Pd-GOD was integrated in a flow injection system and used for discrete glucose monitoring of a bioprocess. Stability, reproducibility and flow parameters related to the flow injection system were studied; The analytical system showed a linear response for glucose in the range 10(-5)-10(-2) mol l(-1) when a potential of 900 mV was applied with respect to an Ag/AgCl electrode. A solution-of 0.1 mol l(-1) phosphate and 0.1 mol l(-1) KCl buffered to pH 7 was used as the carrier solution. The reproducibility of the signal was below 5% and the sampling frequency was about 20 samples h(-1). For the final application, the linear working response range was adapted from 1 to 10 g l(-1): of glucose. The results obtained were compared with those obtained with a commercially available glucose. sensor and by HPLC.
引用
收藏
页码:2255 / 2258
页数:4
相关论文
共 9 条
  • [1] AMPEROMETRIC GLUCOSE BIOSENSOR BASED ON A TETRATHIAFULVALENE-MEDIATED EPOXY-GRAPHITE BIOCOMPOSITE
    CESPEDES, F
    MARTINEZFABREGAS, E
    ALEGRET, S
    [J]. ELECTROANALYSIS, 1994, 6 (09) : 759 - 763
  • [2] AMPEROMETRIC ENZYMATIC GLUCOSE ELECTRODE BASED ON AN EPOXY GRAPHITE COMPOSITE
    CESPEDES, F
    MARTINEZFABREGAS, E
    BARTROLI, J
    ALEGRET, S
    [J]. ANALYTICA CHIMICA ACTA, 1993, 273 (1-2) : 409 - 417
  • [3] AMPEROMETRIC GLUCOSE BIOSENSOR BASED ON AN ELECTROCATALYTICALLY BULK-MODIFIED EPOXY-GRAPHITE BIOCOMPOSITE
    CESPEDES, F
    MARTINEZFABREGAS, E
    ALEGRET, S
    [J]. ANALYTICA CHIMICA ACTA, 1993, 284 (01) : 21 - 26
  • [4] A COMPARISON OF GLASSY-CARBON AND CARBON POLYMER COMPOSITE ELECTRODES INCORPORATED INTO ELECTROCHEMICAL DETECTION SYSTEMS FOR HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY
    KAUFFMANN, JM
    LINDERS, CR
    PATRIARCHE, GJ
    [J]. TALANTA, 1988, 35 (03) : 179 - 182
  • [5] AMPEROMETRIC DETERMINATION OF PESTICIDES USING A BIOSENSOR BASED ON A POLISHABLE GRAPHITE-EPOXY BIOCOMPOSITE
    MARTORELL, D
    CESPEDES, F
    MARTINEZFABREGAS, E
    ALEGRET, S
    [J]. ANALYTICA CHIMICA ACTA, 1994, 290 (03) : 343 - 348
  • [6] POLISHABLE AND ROBUST BIOLOGICAL ELECTRODE SURFACES
    WANG, J
    VARUGHESE, K
    [J]. ANALYTICAL CHEMISTRY, 1990, 62 (03) : 318 - 320
  • [7] A POLISHABLE AMPEROMETRIC BIOSENSOR FOR BILIRUBIN
    WANG, J
    OZSOZ, M
    [J]. ELECTROANALYSIS, 1990, 2 (08) : 647 - 650
  • [8] BULK MODIFIED ENZYME ELECTRODES FOR REAGENTLESS DETECTION OF PEROXIDES
    WOLLENBERGER, U
    WANG, J
    OZSOZ, M
    GONZALEZROMERO, E
    SCHELLER, F
    [J]. BIOELECTROCHEMISTRY AND BIOENERGETICS, 1991, 26 (02): : 287 - 296
  • [9] YANG XR, 1989, MIKROCHIM ACTA, V1, P9