SIMULTANEOUS MEASUREMENT OF CORONARY FLOW RESERVE BY LEFT ANTERIOR DESCENDING CORONARY-ARTERY DOPPLER AND GREAT CARDIAC VEIN THERMODILUTION METHODS

被引:26
作者
ROSSEN, JD [1 ]
OSKARSSON, H [1 ]
STENBERG, RG [1 ]
BRAUN, P [1 ]
TALMAN, CL [1 ]
WINNIFORD, MD [1 ]
机构
[1] UNIV IOWA,COLL MED,CTR CARDIOVASC,DEPT INTERNAL MED,IOWA CITY,IA 52242
关键词
D O I
10.1016/0735-1097(92)90109-Z
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Objectives. The objective of this study was to compare left anterior descending coronary artery Doppler Wood flow velocity and great cardiac vein thermodilution blood flow measurements coronary flow reserve and submaximal coronary vasodilation in humans. Background. Reported maximal coronary flow reserve values obtained with the coronary venous thermodilution method are lower than those obtained with other measurement methods. Methods. Thermodilution measurements of great cardiac vein flow in 11 subjects were compared with simultaneous Doppler measurements of changes in left anterior descending coronary flow velocity after intracoronary administration of papaverine, nitroglycerin, iohexol and intravenous administration of dipyridamole. Results. Coronary flow reserve (papaverine peak/rest flow ratio) was 3.7 +/- 1.7 (mean +/- SD) by the Doppler method and 2.0 +/- 0.7 by the thermodilution technique (p < 0.001). Thermodilution flow changes were also smaller than Doppler-measured changes during submaximal vasodilation and during prolonged coronary dilation after dipyridamole administration. Conclusions. Coronary flow reserve and submaximal flow increases measured with the thermodilution method were consistently and substantially smaller than Doppler-derived measurements. This discrepancy has important implications for the comparison of coronary flow reserve measurements performed with the use of different techniques.
引用
收藏
页码:402 / 407
页数:6
相关论文
共 23 条
[11]   METHODS OF MEASUREMENT OF MYOCARDIAL BLOOD-FLOW IN PATIENTS - A CRITICAL-REVIEW [J].
MARCUS, ML ;
WILSON, RF ;
WHITE, CW .
CIRCULATION, 1987, 76 (02) :245-253
[12]   QUANTITATION OF ANTERIOR DESCENDING VS CIRCUMFLEX VENOUS DRAINAGE IN CANINE GREAT CARDIAC VEIN AND CORONARY SINUS [J].
NAKAZAWA, HK ;
ROBERTS, DL ;
KLOCKE, FJ .
AMERICAN JOURNAL OF PHYSIOLOGY, 1978, 234 (02) :H163-H166
[13]   INVIVO VALIDATION OF A THERMODILUTION METHOD TO DETERMINE REGIONAL LEFT-VENTRICULAR BLOOD-FLOW IN PATIENTS WITH CORONARY-DISEASE [J].
PEPINE, CJ ;
MEHTA, J ;
WEBSTER, WW ;
NICHOLS, WW .
CIRCULATION, 1978, 58 (05) :795-802
[14]   TRANSIENT MYOCARDIAL DYSFUNCTION DURING PHARMACOLOGICAL VASODILATION AS AN INDEX OF REDUCED CORONARY RESERVE - A CORONARY HEMODYNAMIC AND ECHOCARDIOGRAPHIC STUDY [J].
PICANO, E ;
SIMONETTI, I ;
MASINI, M ;
MARZILLI, M ;
LATTANZI, F ;
DISTANTE, A ;
DENES, M ;
LABBATE, A .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1986, 8 (01) :84-90
[15]  
Reiber J H, 1984, IEEE Trans Med Imaging, V3, P131, DOI 10.1109/TMI.1984.4307669
[16]  
RITTMAN EL, 1990, CIRCULATION, V82, P1533
[17]   CORONARY DILATION WITH STANDARD DOSE DIPYRIDAMOLE AND DIPYRIDAMOLE COMBINED WITH HANDGRIP [J].
ROSSEN, JD ;
SIMONETTI, I ;
MARCUS, ML ;
WINNIFORD, MD .
CIRCULATION, 1989, 79 (03) :566-572
[18]   CORONARY HEMODYNAMICS DURING PERCUTANEOUS TRANS-LUMINAL CORONARY ANGIOPLASTY [J].
ROTHMAN, MT ;
BAIM, DS ;
SIMPSON, JB ;
HARRISON, DC .
AMERICAN JOURNAL OF CARDIOLOGY, 1982, 49 (07) :1615-1622
[19]   ACCURACY OF 20-MHZ DOPPLER CATHETER CORONARY-ARTERY VELOCIMETRY FOR MEASUREMENT OF CORONARY BLOOD-FLOW VELOCITY [J].
TADAOKA, S ;
KAGIYAMA, M ;
HIRAMATSU, O ;
OGASAWARA, Y ;
TSUJIOKA, K ;
WADA, Y ;
SAWAYAMA, T ;
KAJIYA, F .
CATHETERIZATION AND CARDIOVASCULAR DIAGNOSIS, 1990, 19 (03) :205-213
[20]   TRANS-LUMINAL, SUBSELECTIVE MEASUREMENT OF CORONARY-ARTERY BLOOD-FLOW VELOCITY AND VASODILATOR RESERVE IN MAN [J].
WILSON, RF ;
LAUGHLIN, DE ;
ACKELL, PH ;
CHILIAN, WM ;
HOLIDA, MD ;
HARTLEY, CJ ;
ARMSTRONG, ML ;
MARCUS, ML ;
WHITE, CW .
CIRCULATION, 1985, 72 (01) :82-92