CARE-LASS (CALCEIN-RELEASE-ASSAY), AN IMPROVED FLUORESCENCE-BASED TEST SYSTEM TO MEASURE CYTOTOXIC T-LYMPHOCYTE ACTIVITY

被引:225
作者
LICHTENFELS, R
BIDDISON, WE
SCHULZ, H
VOGT, AB
MARTIN, R
机构
[1] UNIV TUBINGEN,SCH MED,DEPT NEUROL,D-72076 TUBINGEN,GERMANY
[2] NINCDS,MOLEC IMMUNOL SECT,NEUROIMMUNOL BRANCH,BETHESDA,MD 20892
关键词
ACETOXYMETHYL ESTER OF CALCEIN; FLUOROMETRIC MICROASSAY; T CELL CYTOTOXICITY ASSAY; LYMPHOKINE ACTIVATED KILLER ASSAY;
D O I
10.1016/0022-1759(94)90110-4
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
CARE-LASS is a highly sensitive, fast, simple and safe fluorometric microassay. Target cells are loaded with acetoxymethyl ester of calcein (calcein-AM) that passively crosses the cell membrane. Intracellular esterases convert the molecule to calcein, a polar fluorochrome which, in cells with intact plasma membranes, displays good retention characteristics and low pH sensitivity. In analogy to standard Cr-51 release assays, the CARE-LASS system is based on the release of a marker into the supernatant that is measured by an automated fluorescence scanner and correlates with the number of lysed cells. We tested the CARE-LASS system by measuring cytotoxicity in major histocompatibility complex (MHC) class I and MHC class II restricted cytotoxic T lymphocyte (CTL) assays as well as lymphokine activated killer (LAK) mediated cytotoxicity. We applied a small set of target cell lines at various effector to target (E:T) ratios, at different antigen concentrations and compared CARE-LASS CTL data to data resulting from conventional Cr-51 release assays. The CARE-LASS system provides a reliable and sensitive method to measure cell-mediated cytotoxicity.
引用
收藏
页码:227 / 239
页数:13
相关论文
共 37 条
[1]   A RAPID CELL-MEMBRANE PERMEABILITY TEST USING FLUORESCENT DYES AND FLOW-CYTOMETRY [J].
AESCHBACHER, M ;
REINHARDT, CA ;
ZBINDEN, G .
CELL BIOLOGY AND TOXICOLOGY, 1986, 2 (02) :247-255
[2]   A NEW ASSAY FOR CELL-DEATH [J].
BELETSKY, IP ;
UMANSKY, SR .
JOURNAL OF IMMUNOLOGICAL METHODS, 1990, 134 (02) :201-205
[3]   EUROPIUM-LABELED TARGET-CELLS IN AN ASSAY OF NATURAL-KILLER CELL-ACTIVITY .2. A NOVEL NONRADIOACTIVE METHOD BASED ON TIME-RESOLVED FLUORESCENCE - SIGNIFICANCE AND SPECIFICITY OF THE METHOD [J].
BLOMBERG, K ;
GRANBERG, C ;
HEMMILA, I ;
LOVGREN, T .
JOURNAL OF IMMUNOLOGICAL METHODS, 1986, 92 (01) :117-123
[4]   EUROPIUM-LABELED TARGET-CELLS IN AN ASSAY OF NATURAL-KILLER CELL-ACTIVITY .1. A NOVEL NONRADIOACTIVE METHOD BASED ON TIME-RESOLVED FLUORESCENCE [J].
BLOMBERG, K ;
GRANBERG, C ;
HEMMILA, I ;
LOVGREN, T .
JOURNAL OF IMMUNOLOGICAL METHODS, 1986, 86 (02) :225-229
[5]   AUTOMATED FLUOROMETRIC ASSAY FOR T-CELL CYTO-TOXICITY [J].
BRENAN, M ;
PARISH, CR .
JOURNAL OF IMMUNOLOGICAL METHODS, 1988, 112 (01) :121-131
[6]   CARBOXYFLUORESCEIN FLUOROCHROMASIA ASSAYS .1. NON-RADIOACTIVELY LABELED CELL-MEDIATED LYMPHOLYSIS [J].
BRUNING, JW ;
KARDOL, MJ ;
ARENTZEN, R .
JOURNAL OF IMMUNOLOGICAL METHODS, 1980, 33 (01) :33-44
[7]  
BRUNNER KT, 1968, IMMUNOLOGY, V14, P181
[8]   CHARACTERIZATION OF EFFECTOR-TARGET CONJUGATES FOR CLONED HUMAN NATURAL-KILLER AND HUMAN LYMPHOKINE ACTIVATED KILLER-CELLS BY FLOW-CYTOMETRY [J].
CALLEWAERT, DM ;
RADCLIFF, G ;
WAITE, R ;
LEFEVRE, J ;
POULIK, MD .
CYTOMETRY, 1991, 12 (07) :666-676
[9]  
DIBRINO M, 1993, J IMMUNOL, V151, P5930
[10]   A SENSITIVE ASSAY OF CYTO-TOXICITY APPLICABLE TO MIXED CELL-POPULATIONS [J].
DUERST, RE ;
FRANTZ, CN .
JOURNAL OF IMMUNOLOGICAL METHODS, 1985, 82 (01) :39-46