COMPARISON OF BONE-IMPLANT INTERFACE SHEAR-STRENGTH OF SOLID HYDROXYAPATITE AND HYDROXYAPATITE-COATED TITANIUM IMPLANTS

被引:84
作者
HAYASHI, K
INADOME, T
MASHIMA, T
SUGIOKA, Y
机构
[1] Department of Orthopaedic Surgery, Faculty of Medicine, Kyushu University, Fukuoka, 812, 3-1-1 Maidashi, Higashi-ku
来源
JOURNAL OF BIOMEDICAL MATERIALS RESEARCH | 1993年 / 27卷 / 05期
关键词
D O I
10.1002/jbm.820270502
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
The interface shear strength of uncoated Ti-6Al-4V, dense sintered hydroxyapatite (HA), and HA-coated Ti-6Al-4V were compared. Interface shear strength was determined using a transcortical push-out model in dogs 4 and 12 weeks after implantation. The interface shear strength of dense sintered HA and HA-coated Ti-6Al-4V was significantly higher than that of uncoated Ti-6Al-4V (P < .001). There was no significant difference between the interface shear strength of dense sintered HA and HA-coated Ti-6Al-4V. After the push-out test for HA-coated implants, the regions fractured at the bone-coating interface and at the coating-titanium interface coexisted at 4 weeks after implantation. At 12 weeks, the fracture site was, in all cases, the HA coating-titanium interface, and, in a few samples, fractures inside the coating layer also were visible.
引用
收藏
页码:557 / 563
页数:7
相关论文
共 17 条
[1]   HYDROXYAPATITE-COATED FEMORAL STEMS - HISTOLOGICAL ANALYSIS OF COMPONENTS RETRIEVED AT AUTOPSY [J].
BAUER, TW ;
GEESINK, RCT ;
ZIMMERMAN, R ;
MCMAHON, JT .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1991, 73A (10) :1439-1452
[2]  
COOK SD, 1988, CLIN ORTHOP RELAT R, V232, P225
[3]   INTERFACE BETWEEN BONE TISSUE AND IMPLANTS OF SOLID HYDROXYAPATITE OR HYDROXYAPATITE-COATED TITANIUM IMPLANTS [J].
DELANGE, GL ;
DONATH, K .
BIOMATERIALS, 1989, 10 (02) :121-125
[4]   A MECHANICAL INVESTIGATION OF FLUORAPATITE, MAGNESIUMWHITLOCKITE, AND HYDROXYLAPATITE PLASMA-SPRAYED COATINGS IN GOATS [J].
DHERT, WJA ;
KLEIN, CPAT ;
WOLKE, JGC ;
VANDERVELDE, EA ;
DEGROOT, K ;
ROZING, PM .
JOURNAL OF BIOMEDICAL MATERIALS RESEARCH, 1991, 25 (10) :1183-1200
[5]   EFFECT OF HYDROXYAPATITE IMPREGNATION ON SKELETAL BONDING OF POROUS COATED IMPLANTS [J].
DUCHEYNE, P ;
HENCH, LL ;
KAGAN, A ;
MARTENS, M ;
BURSENS, A ;
MULIER, JC .
JOURNAL OF BIOMEDICAL MATERIALS RESEARCH, 1980, 14 (03) :225-237
[6]   BONDING OF BONE TO APATITE-COATED IMPLANTS [J].
GEESINK, RGT ;
DEGROOT, K ;
KLEIN, CPAT .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1988, 70 (01) :17-22
[7]  
GEESINK RGT, 1990, CLIN ORTHOP RELAT R, V261, P39
[8]   QUANTITATIVE-ANALYSIS OF INVIVO TISSUE RESPONSES TO TITANIUM-OXIDE-COATED AND HYDROXYAPATITE-COATED TITANIUM-ALLOY [J].
HAYASHI, K ;
UENOYAMA, K ;
MATSUGUCHI, N ;
SUGIOKA, Y .
JOURNAL OF BIOMEDICAL MATERIALS RESEARCH, 1991, 25 (04) :515-523
[9]   BREAKDOWN CORROSION POTENTIAL OF CERAMIC COATED METAL IMPLANTS [J].
HAYASHI, K ;
NODA, I ;
UENOYAMA, K ;
SUGIOKA, Y .
JOURNAL OF BIOMEDICAL MATERIALS RESEARCH, 1990, 24 (08) :1111-1113
[10]   REEVALUATION OF THE BIOCOMPATIBILITY OF BIOINERT CERAMICS INVIVO [J].
HAYASHI, K ;
MATSUGUCHI, N ;
UENOYAMA, K ;
SUGIOKA, Y .
BIOMATERIALS, 1992, 13 (04) :195-200