FALSE-POSITIVE DOBUTAMINE STRESS ECHOCARDIOGRAMS - CHARACTERIZATION OF CLINICAL, ECHOCARDIOGRAPHIC AND ANGIOGRAPHIC FINDINGS

被引:96
作者
BACH, DS
MULLER, DWM
GROS, BJ
ARMSTRONG, WF
机构
[1] Department of Internal Medicine, Division of Cardiology, University of Michigan, Ann Arbor, MI
关键词
D O I
10.1016/0735-1097(94)90851-6
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Objectives. This study was designed to characterize the clinical, echocardiographic and angiographic findings in patients who have regional wall motion abnormalities predictive of coronary artery disease on dobutamine stress echocardiograms, although coronary angiography reveals no critical stenoses. Background. The specificity of dobutamine stress echocardiog raphy has been reported to be lower than its sensitivity; tile sources of false positive findings on dobutamine stress echocardiograms have not been previously defined. Methods. Clinical and echocardiographic characteristics were retrospectively reviewed for patients who had both a dobutamine stress echocardiogram indicative of coronary artery disease on tile basis of wall motion abnormalities and <50% stenoses reported on coronary angiography performed within 6 weeks of the echocardiogram. A 16-segment model was used to perform wall motion scoring. Angiograms were independently reviewed, and stenosis severity was quantified with the use of digital calipers. Results. Thirty nine (11.4%) of 342 studies met criteria for faire positive test results, which occurred predominantly in women (72%, p < 0.001). Regional wall motion abnormalities were evident more often in the posterior circulation (62%), and 65% of them were limited to the basal segments. Twelve (28%) of 43 wall motion abnormalities were associated with coronary stenoses of at least intermediate grade (lumen diameter 40.3% to 68.1%). Abnormalities confined to basal segments of the posterior circulation were unlikely to have associated coronary lesions (p = 0.03). Conclusions. False positive findings on dobutamine stress echocardiograms tend to involve small wall motion abnormalities that are frequently located in basal segments of the posterior myocardial circulation. Approximately one third of false positive results occurred in patients with intermediate-grade coronary stenoses, and these studies may reflect true inducible ischemia. Additional sources of false positive study results may include poor endocardial visualization and abnormal motion due to tethering to the fibrous skeleton of the heart. Altered echocardiographic diagnostic criteria may be appropriate for small wall motion abnormalities confined to basal segments of the posterior circulation.
引用
收藏
页码:928 / 933
页数:6
相关论文
共 11 条
  • [1] EFFECT OF PRIOR MYOCARDIAL-INFARCTION AND EXTENT AND LOCATION OF CORONARY-DISEASE ON ACCURACY OF EXERCISE ECHOCARDIOGRAPHY
    ARMSTRONG, WF
    ODONNELL, J
    RYAN, T
    FEIGENBAUM, H
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1987, 10 (03) : 531 - 538
  • [2] DOBUTAMINE STRESS ECHOCARDIOGRAPHY - PREVALENCE OF A NONISCHEMIC RESPONSE IN A LOW-RISK POPULATION
    BACH, DS
    HEPNER, A
    MARCOVITZ, PA
    ARMSTRONG, WF
    [J]. AMERICAN HEART JOURNAL, 1993, 125 (05) : 1257 - 1261
  • [3] DOBUTAMINE DIGITAL ECHOCARDIOGRAPHY FOR DETECTING CORONARY-ARTERY DISEASE
    COHEN, JL
    GREENE, TO
    OTTENWELLER, J
    BINENBAUM, SZ
    WILCHFORT, SD
    KIM, CS
    [J]. AMERICAN JOURNAL OF CARDIOLOGY, 1991, 67 (16) : 1311 - 1318
  • [4] KRAUSE LJ, 1993, J AM COLL CARDIOL, V22, P1494
  • [5] ACCURACY OF DOBUTAMINE STRESS ECHOCARDIOGRAPHY IN DETECTING CORONARY-ARTERY DISEASE
    MARCOVITZ, PA
    ARMSTRONG, WF
    [J]. AMERICAN JOURNAL OF CARDIOLOGY, 1992, 69 (16) : 1269 - 1273
  • [6] COMPARISON OF ADENOSINE, DIPYRIDAMOLE, AND DOBUTAMINE IN STRESS ECHOCARDIOGRAPHY
    MARTIN, TW
    SEAWORTH, JF
    JOHNS, JP
    PUPA, LE
    CONDOS, WR
    [J]. ANNALS OF INTERNAL MEDICINE, 1992, 116 (03) : 190 - 196
  • [7] DOBUTAMINE STRESS ECHOCARDIOGRAPHY FOR DETECTION AND ASSESSMENT OF CORONARY-ARTERY DISEASE
    MAZEIKA, PK
    NADAZDIN, A
    OAKLEY, CM
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1992, 19 (06) : 1203 - 1211
  • [8] INTRAVASCULAR ULTRASOUND STUDY OF ANGIOGRAPHICALLY MILDLY DISEASED CORONARY-ARTERIES
    PORTER, TR
    SEARS, T
    XIE, F
    MICHELS, A
    MATA, J
    WELSH, D
    SHURMUR, S
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1993, 22 (07) : 1858 - 1865
  • [9] ECHOCARDIOGRAPHIC DETECTION OF CORONARY-ARTERY DISEASE DURING DOBUTAMINE INFUSION
    SAWADA, SG
    SEGAR, DS
    RYAN, T
    BROWN, SE
    DOHAN, AM
    WILLIAMS, R
    FINEBERG, NS
    ARMSTRONG, WF
    FEIGENBAUM, H
    [J]. CIRCULATION, 1991, 83 (05) : 1605 - 1614
  • [10] A NEW DIGITAL ELECTRONIC CALIPER FOR MEASUREMENT OF CORONARY ARTERIAL-STENOSIS - COMPARISON WITH VISUAL ESTIMATES AND COMPUTER-ASSISTED MEASUREMENTS
    SCOBLIONKO, DP
    BROWN, BG
    MITTEN, S
    CALDWELL, JH
    KENNEDY, JW
    BOLSON, EL
    DODGE, HT
    [J]. AMERICAN JOURNAL OF CARDIOLOGY, 1984, 53 (06) : 689 - 693