TECHNICAL EVALUATION OF A DIGITAL CHEST RADIOGRAPHY SYSTEM THAT USES A SELENIUM DETECTOR

被引:44
作者
CHOTAS, HG [1 ]
FLOYD, CE [1 ]
RAVIN, CE [1 ]
机构
[1] DUKE UNIV,DEPT BIOMED ENGN,DURHAM,NC 27710
关键词
LUNG; RADIOGRAPHY; COMPARATIVE STUDIES; DIGITAL; THORAX;
D O I
10.1148/radiology.195.1.7892483
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
PURPOSE: To evaluate a digital chest radiography system that uses a selenium detector. MATERIALS AND METHODS: The relative amounts of scattered radiation in the images (scatter fractions), the effect of x-ray exposure levels on image appearance, the potential ''throughput'' in a clinical environment, and the effects of image processing options were evaluated. RESULTS: Scatter fractions in digital images acquired with an antiscatter grid were lower in the lung region and higher in the retrocardiac and central mediastinal regions than in conventional images. Digital images acquired without an antiscatter grid had higher scatter fractions in all areas. Increases in exposure intensity reduced the appearance of noise. A new image could be acquired every 37 seconds, and a ''preview image'' appeared on the monitor after approximately 23 seconds. Laser-printed images were available after at least 5 minutes; the time required increased when many images were acquired in a short time. CONCLUSION: The selenium-based chest radiography system allows for rapid chest examination and excellent image quality when used with an antiscatter grid.
引用
收藏
页码:264 / 270
页数:7
相关论文
共 18 条
[1]  
BUNCH PC, 1992, P SOC PHOTO-OPT INS, V1653, P46, DOI 10.1117/12.59484
[2]   COMPARISON OF THE LOW-CONTRAST DETECTABILITY OF A SCREEN-FILM SYSTEM AND 3RD-GENERATION COMPUTED RADIOGRAPHY [J].
COOK, LT ;
INSANA, MF ;
MCFADDEN, MA ;
HALL, TJ ;
COX, GG .
MEDICAL PHYSICS, 1994, 21 (05) :691-695
[3]   THRESHOLD PERCEPTION PERFORMANCE WITH COMPUTED AND SCREEN-FILM RADIOGRAPHY - IMPLICATIONS FOR CHEST RADIOGRAPHY [J].
DOBBINS, JT ;
RICE, JJ ;
BEAM, CA ;
RAVIN, CE .
RADIOLOGY, 1992, 183 (01) :179-187
[4]  
FLOYD CE, 1994, P SOC PHOTO-OPT INS, V2163, P110
[5]   MEASUREMENT OF SCATTER FRACTIONS IN CLINICAL BEDSIDE RADIOGRAPHY [J].
FLOYD, CE ;
BAKER, JA ;
LO, JY ;
RAVIN, CE .
RADIOLOGY, 1992, 183 (03) :857-861
[6]   IMAGING PERFORMANCE OF A DIGITAL STORAGE PHOSPHOR SYSTEM [J].
HILLEN, W ;
SCHIEBEL, U ;
ZAENGEL, T .
MEDICAL PHYSICS, 1987, 14 (05) :744-751
[7]  
HILLEN W, 1989, P SOC PHOTO-OPT INS, V1090, P296
[8]   GRIDS OR AIR GAPS FOR SCATTER REDUCTION IN DIGITAL RADIOGRAPHY - A MODEL CALCULATION [J].
NEITZEL, U .
MEDICAL PHYSICS, 1992, 19 (02) :475-481
[9]   IMAGE QUALITY OF A DIGITAL CHEST RADIOGRAPHY SYSTEM BASED ON A SELENIUM DETECTOR [J].
NEITZEL, U ;
MAACK, I ;
GUNTHERKOHFAHL, S .
MEDICAL PHYSICS, 1994, 21 (04) :509-516
[10]   SCATTERED RADIATION IN CHEST RADIOGRAPHY [J].
NIKLASON, LT ;
SORENSON, JA ;
NELSON, JA .
MEDICAL PHYSICS, 1981, 8 (05) :677-681