摘要
A large variety of optical sensors based on thin plasticized PVC membranes have been realized in the past. The organic membrane (bulk optode) contains the analyte recognition molecule such as a selective neutral ionophore, a H+-selective chromolonophore, and lipophilic anionic sites. In order to improve the lifetime of analytically relevant sensing layers, their active components are covalently immobilized to the polymeric matrix. Different Ca2+-selective bulk optodes with mobile or fixed chromolonophores and anionic sites are characterized and discussed with respect to sensor behavior such as dynamic range, repeatability, response time, selectivity, and lifetime. In general, the response time increases upon immobilization of components owing to limited diffusion within the membrane phase, whereas the lifetime is enhanced drastically by a hindered loss of membrane components Into the sample.
引用
收藏
页码:2029 / 2035
页数:7
相关论文
共 25 条
  • [1] AN OPTICAL CALCIUM-ION SENSOR
    ASHWORTH, DC
    HUANG, HP
    NARAYANASWAMY, R
    [J]. ANALYTICA CHIMICA ACTA, 1988, 213 (1-2) : 251 - 257
  • [2] OPTICAL SENSOR FOR CALCIUM - PERFORMANCE, STRUCTURE, AND REACTIVITY OF CALCICHROME IMMOBILIZED AT AN ANIONIC POLYMER FILM
    CHAU, LK
    PORTER, MD
    [J]. ANALYTICAL CHEMISTRY, 1990, 62 (18) : 1964 - 1971
  • [3] LIFETIME OF NEUTRAL-CARRIER-BASED LIQUID MEMBRANES IN AQUEOUS SAMPLES AND BLOOD AND THE LIPOPHILICITY OF MEMBRANE-COMPONENTS
    DINTEN, O
    SPICHIGER, UE
    CHANIOTAKIS, N
    GEHRIG, P
    RUSTERHOLZ, B
    MORF, WE
    SIMON, W
    [J]. ANALYTICAL CHEMISTRY, 1991, 63 (06) : 596 - 603
  • [4] Fabry C., 1899, ANN CHIM PHYS, V16, P115
  • [5] GEHRIG P, 1989, CHIMIA, V43, P377
  • [6] VERY LIPOPHILIC SODIUM-SELECTIVE IONOPHORE FOR CHEMICAL SENSORS OF HIGH LIFETIME
    GEHRIG, P
    RUSTERHOLZ, B
    SIMON, W
    [J]. ANALYTICA CHIMICA ACTA, 1990, 233 (02) : 295 - 298
  • [7] CATALYSIS OF ION TRANSFER BY TETRAPHENYLBORATES IN NEUTRAL CARRIER-BASED ION-SELECTIVE ELECTRODES
    GEHRIG, P
    MORF, WE
    WELTI, M
    PRETSCH, E
    SIMON, W
    [J]. HELVETICA CHIMICA ACTA, 1990, 73 (01) : 203 - 212
  • [8] Hansch C., 1979, SUBSTITUENT CONSTANT
  • [9] DO OPTICAL SENSORS REALLY MEASURE PH
    JANATA, J
    [J]. ANALYTICAL CHEMISTRY, 1987, 59 (09) : 1351 - 1356
  • [10] JANATA J, 1990, ANAL CHEM, V62, pR33, DOI 10.1021/ac00211a017