摘要
Deviations of the position of the isocenter were quantitatively assessed for CT-based limited volume irradiation of brain tumors. Of the linear deviations, 95% were within 10 mm and 3 mm during treatment planning and delivery, respectively. The application of face masks before CT planning improved the accuracy of field alignment. Repeated CT examinations seemed to be more important after simulation than during treatment delivery.
引用
收藏
页码:171 / 174
页数:4
相关论文
共 6 条
[1]   TOPOGRAPHIC ANATOMY AND CT CORRELATIONS IN THE UNTREATED GLIOBLASTOMA-MULTIFORME [J].
BURGER, PC ;
HEINZ, ER ;
SHIBATA, T ;
KLEIHUES, P .
JOURNAL OF NEUROSURGERY, 1988, 68 (05) :698-704
[2]   QUALITY-CONTROL AT THE PATIENT LEVEL - ACTION OR RETROSPECTIVE INTROSPECTION [J].
DUTREIX, A ;
VANDERSCHUEREN, E ;
LEUNENS, L .
RADIOTHERAPY AND ONCOLOGY, 1992, 25 (02) :146-147
[3]   DETECTION OF SYSTEMATIC PATIENT SETUP ERRORS BY PORTAL FILM ANALYSIS [J].
LEBESQUE, JV ;
BEL, A ;
BIJHOLD, J ;
HART, AAM .
RADIOTHERAPY AND ONCOLOGY, 1992, 23 (03) :198-198
[4]   IS IT NECESSARY TO REPEAT QUALITY-CONTROL PROCEDURES FOR HEAD AND NECK PATIENTS [J].
MITINE, C ;
LEUNENS, G ;
VERSTRAETE, J ;
BLANCKAERT, N ;
VANDAM, J ;
DUTREIX, A ;
VANDERSCHUEREN, E .
RADIOTHERAPY AND ONCOLOGY, 1991, 21 (03) :201-210
[5]   3-DIMENSIONAL MOTION ANALYSIS OF AN IMPROVED HEAD IMMOBILIZATION SYSTEM FOR SIMULATION, CT, MRI, AND PET IMAGING [J].
THORNTON, AF ;
TENHAKEN, RK ;
GERHARDSSON, A ;
CORRELL, M .
RADIOTHERAPY AND ONCOLOGY, 1991, 20 (04) :224-228
[6]  
1978, ICRU29 INT COMM RAD