ONLINE PRECONCENTRATION AND LIQUID-CHROMATOGRAPHIC ANALYSIS OF PHENYLUREA PESTICIDES IN ENVIRONMENTAL WATER USING A SILICA-BASED IMMUNOSORBENT

被引:44
作者
PICHON, V [1 ]
CHEN, L [1 ]
HENNION, MC [1 ]
机构
[1] ECOLE SUPER PHYS & CHIM IND VILLE PARIS,CHIM ANALYT LAB,CNRS,URA 437,F-75231 PARIS 05,FRANCE
关键词
LIQUID CHROMATOGRAPHY; IMMUNOASSAY; PRECONCENTRATION; PESTICIDES; PHENYLUREA PESTICIDES; ENVIRONMENTAL ANALYSIS;
D O I
10.1016/0003-2670(95)00160-2
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The feasibility of using a silica-based immunosorbent for the selective on-line preconcentration of several phenylurea pesticides in drinking and surface waters was demonstrated. The immunosorbent was packed in a precolumn which was used in the same way as a conventional C-18 or PLRP-S precolumn: percolation of aqueous samples through the precolumn, then direct coupling to a C-18 analytical column and desorption using an acetonitrile gradient from 20 to 80% acetonitrile. Although the retention of the different phenylureas was based on antigen-antibody interactions in the precolumn and on hydrophobic interactions in the analytical column, the efficiency of the on-line system was excellent as shown by the on-line preconcentration and analysis of 12 phenylureas of different polarities. The characteristics of the immunosorbent (cross-reactivity, breakthrough of analytes, capacity, selectivity and reusability) were discussed. An application to the analysis of surface waters showed the high selectivity of this sorbent. Detection limits from a 50-ml sample were ranging between 0.05 and 0.5 mu g/l for 10 phenylureas in a mixture of 13. An application to the rapid monitoring of isoproturon in the river Seine was also reported.
引用
收藏
页码:429 / 436
页数:8
相关论文
共 19 条
  • [1] IMMUNOAFFINITY PRE-COLUMN FOR SELECTIVE ONLINE SAMPLE PRE-TREATMENT IN HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY DETERMINATION OF 19-NORTESTOSTERONE
    FARJAM, A
    DEJONG, GJ
    FREI, RW
    BRINKMAN, UAT
    HAASNOOT, W
    HAMERS, ARM
    SCHILT, R
    HUF, FA
    [J]. JOURNAL OF CHROMATOGRAPHY, 1988, 452 : 419 - 433
  • [2] IMMUNO PRECOLUMNS FOR SELECTIVE ONLINE SAMPLE PRETREATMENT OF AFLATOXINS IN MILK PRIOR TO COLUMN LIQUID-CHROMATOGRAPHY
    FARJAM, A
    DEVRIES, R
    LINGEMAN, H
    BRINKMAN, UAT
    [J]. INTERNATIONAL JOURNAL OF ENVIRONMENTAL ANALYTICAL CHEMISTRY, 1991, 44 (03) : 175 - 184
  • [3] NONSELECTIVE DESORPTION OF IMMUNO PRECOLUMNS COUPLED ONLINE WITH COLUMN LIQUID-CHROMATOGRAPHY - DETERMINATION OF AFLATOXINS
    FARJAM, A
    VANDEMERBEL, NC
    LINGEMAN, H
    FREI, RW
    BRINKMAN, UAT
    [J]. INTERNATIONAL JOURNAL OF ENVIRONMENTAL ANALYTICAL CHEMISTRY, 1991, 45 (02) : 73 - 87
  • [4] FARJAM A, 1991, THESIS FREE U AMSTER
  • [5] SOLID-PHASE EXTRACTION IN MULTI-RESIDUE PESTICIDE ANALYSIS OF WATER
    FONT, G
    MANES, J
    MOLTO, JC
    PICO, Y
    [J]. JOURNAL OF CHROMATOGRAPHY, 1993, 642 (1-2): : 135 - 161
  • [6] DETERMINATION OF BETA-19-NORTESTOSTERONE AND ITS METABOLITE ALPHA-19-NORTESTOSTERONE IN BIOLOGICAL SAMPLES AT THE SUB PARTS PER BILLION LEVEL BY HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY WITH ONLINE IMMUNOAFFINITY SAMPLE PRETREATMENT
    HAASNOOT, W
    SCHILT, R
    HAMERS, ARM
    HUF, FA
    FARJAM, A
    FREI, RW
    BRINKMAN, UAT
    [J]. JOURNAL OF CHROMATOGRAPHY-BIOMEDICAL APPLICATIONS, 1989, 489 (01): : 157 - 171
  • [7] HPLC ANALYSIS OF HUMAN EPIDERMAL GROWTH-FACTOR USING IMMUNOAFFINITY PRECOLUMN .1. OPTIMIZATION OF IMMUNOAFFINITY COLUMN
    HAYASHI, T
    SAKAMOTO, S
    SHIKANABE, M
    WADA, I
    YOSHIDA, H
    [J]. CHROMATOGRAPHIA, 1989, 27 (11-12) : 569 - 573
  • [8] HENNION MC, 1993, ENV ANAL TECHNIQUES, P23
  • [9] JOHANSSON B, 1989, J CHROMATOGR, V381, P107
  • [10] NIELEN MWF, 1989, J CHROMATOGRAPHY L A, V39, P5