THE RELATION BETWEEN INVASIVE AND NONINVASIVE TEAR BREAK-UP TIME

被引:69
作者
CHO, P
DOUTHWAITE, W
机构
[1] Department of Optometry and Radiography, Hong Kong Polytechnic University, Kowloon, HKG, Hung Horn
[2] Department of Optometry, University of Bradford, Bradford, West Yorkshire
关键词
TBUT; NITBUT; NIBUT; CHINESE; CAUCASIAN; AGREEMENT; CORRELATION;
D O I
10.1097/00006324-199501000-00004
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
TBUT and NITBUT (tear break-up time and noninvasive tear break-up time, respectively) were measured on four groups of subjects from different countries (two groups of Caucasians, two groups of Chinese). No significant difference was found in either TBUT or NITBUT values among the four groups of subjects. Gender of the subjects was not a factor affecting the TBUT or NITBUT values. The distributions of both NITBUT and TBUT were non-Gaussian and the median value of either parameter was lower than those previously reported. The NITBUT values were significantly higher than the TBUT values in both Caucasian and Chinese subjects. An investigation into the extent of agreement between the TBUT and NITBUT methods of assessing tear stability indicated that these methods do not agree sufficiently closely (that is, tear stability Values measured with the NITBUT technique do not agree with those measured with the TBUT technique); short average tear break-up values are associated with small differences between the measures, whereas long average tear break-up values are associated with large differences between the measures.
引用
收藏
页码:17 / 22
页数:6
相关论文
共 27 条
[1]  
Lemp M.A., Hamill J.R., Factors affecting tear film breakup in normal eyes, Arch Ophthalmol, 89, pp. 103-105, (1973)
[2]  
Norn M.S., Desiccation of the precorneal film, I: Corneal Wet-Ting-Time. Acta Ophthalmol (Kbh), 47, pp. 865-880, (1969)
[3]  
Norn M.S., Tear film break-up time: A review, The Preocular Tear Film in Health, Disease and Contact Lens Wear, pp. 52-56, (1986)
[4]  
Mengher L.S., Bron A.J., Tonge S.R., Gilbert D.J., Effect of fluorescein instillation on the pre-corneal tear film stability, Curr Eye Res, 4, pp. 9-12, (1985)
[5]  
Mengher L.S., Bron A.J., Tonge S.R., Gilbert D.J., A non-lnvasive instrument for clinical assessment of the precorneal tear film stability, Curr Eye Res, 4, pp. 1-7, (1985)
[6]  
Tonge S.R., Hunsaker J., Holly F.J., Non-invasive assessment of tear film break-up time in a group of normal subjects -implications for contact lens wear, J Br Contact Lens Assoc, 14, pp. 201-205, (1991)
[7]  
Patel S., Murray D., McKenzie A., Shearer D.S., McGrath B.D., Effects of fluorescein on tear breakup time and on tear thinning time, Am J Optom Physiol Opt, 62, pp. 188-190, (1985)
[8]  
Guillon J.P., Observing and photographing the precorneal and prelens tear film, Contax, pp. 15-22, (1986)
[9]  
Efron N., Golding T.R., Brennan N.A., pp. 14-19, (1990)
[10]  
Faber E., Golding T.R., Lowe R., Brennan N.A., Effect of hydrogel lens wear on tear film stability, Optom Vis Sci, 68, pp. 380-384, (1991)