THE RELATION BETWEEN INVASIVE AND NONINVASIVE TEAR BREAK-UP TIME

被引:69
作者
CHO, P
DOUTHWAITE, W
机构
[1] Department of Optometry and Radiography, Hong Kong Polytechnic University, Kowloon, HKG, Hung Horn
[2] Department of Optometry, University of Bradford, Bradford, West Yorkshire
关键词
TBUT; NITBUT; NIBUT; CHINESE; CAUCASIAN; AGREEMENT; CORRELATION;
D O I
10.1097/00006324-199501000-00004
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
TBUT and NITBUT (tear break-up time and noninvasive tear break-up time, respectively) were measured on four groups of subjects from different countries (two groups of Caucasians, two groups of Chinese). No significant difference was found in either TBUT or NITBUT values among the four groups of subjects. Gender of the subjects was not a factor affecting the TBUT or NITBUT values. The distributions of both NITBUT and TBUT were non-Gaussian and the median value of either parameter was lower than those previously reported. The NITBUT values were significantly higher than the TBUT values in both Caucasian and Chinese subjects. An investigation into the extent of agreement between the TBUT and NITBUT methods of assessing tear stability indicated that these methods do not agree sufficiently closely (that is, tear stability Values measured with the NITBUT technique do not agree with those measured with the TBUT technique); short average tear break-up values are associated with small differences between the measures, whereas long average tear break-up values are associated with large differences between the measures.
引用
收藏
页码:17 / 22
页数:6
相关论文
共 27 条
[11]  
Mengher L.S., Pandher K.S., Bron A.J., Non-invasive tear film break-up time: Sensitivity and specificity, Acta Ophthalmol (Kbh), 64, pp. 441-444, (1986)
[12]  
Mengher L.S., Pandher K.S., Bron A.J., Davey C.C., Effect of sodium hyaluronate (0.1%) on break-up time (NIBUT) in patients with dry eyes, Br J Ophthalmol, 70, pp. 442-447, (1986)
[13]  
Cho P., Brown B., Review of the tear break-up time and a closer look at the tear break-up time of Hong Kong Chinese, Optom Vis Sci, 70, pp. 30-38, (1993)
[14]  
Cho P., Brown B., The distribution of the invasive and non-invasive tear break-up time of Hong Kong, Chinese Proceedings of the 9Th Asian Pacific Optometrical Congress, pp. 70-73, (1993)
[15]  
Cho P., The reliability of a portable non-invasive tear break-up time test on Hong Kong-Chinese, Optom Vis Sci, 70, pp. 1049-1054, (1993)
[16]  
Brown B., Cho P., Inter- and intra-individual variability of non-invasive tear break-up time in Hong Kong Chinese, Clin Exp Optom, 77, pp. 15-23, (1994)
[17]  
Cho P., Brown B., Chan I., Conway R., Yap M., Reliability of the tear break-up time technique of assessing tear stability and the locations of the tear break-up in Hong Kong Chinese, Optom Vis Sci, 69, pp. 879-885, (1992)
[18]  
Norn M.S., Outflow of tears and its influence on tear secretion and break up time (B.U.T), Acta Ophthalmol (Kbh), 55, pp. 674-682, (1977)
[19]  
Geetlng D.G., Bakar S.R., In vivo comparison of ocular lubricants in patients having reduced tear film breakup times, J Am Optom Assoc, 51, pp. 757-760, (1980)
[20]  
Vanley G.T., Leopold I.H., Gregg T.H., Interpretation of tear film breakup, Arch Ophthalmol, 95, pp. 445-448, (1977)