TOWARDS CONTINUOUS GLUCOSE MONITORING - INVIVO EVALUATION OF A MINIATURIZED GLUCOSE SENSOR IMPLANTED FOR SEVERAL DAYS IN RAT SUBCUTANEOUS TISSUE

被引:108
作者
MOATTISIRAT, D
CAPRON, E
POITOUT, V
REACH, G
BINDRA, DS
ZHANG, Y
WILSON, GS
THEVENOT, DR
机构
[1] HOP HOTEL DIEU,SERV DIABETOL,INSERM,U341,1 PL PARVIS NOTRE DAME,F-75181 PARIS 04,FRANCE
[2] UNIV PARIS 12,LABAM,CRETEIL,FRANCE
[3] UNIV KANSAS,DEPT CHEM,LAWRENCE,KS 66045
关键词
GLUCOSE SENSOR; SUBCUTANEOUS TISSUE;
D O I
10.1007/BF00400921
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
A miniaturized amperometric, enzymatic, glucose sensor (outer diameter 0.45 mm) was evaluated after implantation in the subcutaneous tissue of normal rats. A simple experimental procedure was designed for the long-term assessment of the sensor's function which was performed by recording the current during an intraperitoneal glucose load. The sensor was calibrated by accounting for the increase in the current during the concomitant increase in plasma glucose concentration, determined in blood sampled at the tail vein. This made it possible to estimate the glucose concentration in subcutaneous tissue. During the glucose load, the change in subcutaneous glucose concentration followed that in blood with a lag time consistently shorter than 5 min. The estimations of subcutaneous glucose concentration during these tests were compared to the concomitant plasma glucose concentrations by using a grid analysis. Three days after implantation (n = 6 experiments), 79 estimations were considered accurate, except for five which were in the acceptable zone. Ten days after implantation (n = 5 experiments), 101 estimations were accurate, except for one value, which was still acceptable. The sensitivity was around 0.5 nA . mol-1.l-1 on day 3 and day 10. A longitudinal study on seven sensors tested on different days demonstrated a relative stability of the sensor's sensitivity. Finally, histological examination of the zone around the implantation site revealed a fibrotic reaction containing neocapillaries, which could explain the fast response of the sensor to glucose observed in vivo, even on day 10. We conclude that this miniaturized glucose sensor, whose size makes it easily implanted, works for at least ten days after implantation into rat subcutaneous tissue.
引用
收藏
页码:224 / 230
页数:7
相关论文
共 19 条
  • [1] ABEL P, 1984, BIOMED BIOCHIM ACTA, V43, P577
  • [2] APPLICATION OF CHRONIC INTRAVASCULAR BLOOD-GLUCOSE SENSOR IN DOGS
    ARMOUR, JC
    LUCISANO, JY
    MCKEAN, BD
    GOUGH, DA
    [J]. DIABETES, 1990, 39 (12) : 1519 - 1526
  • [3] DESIGN AND INVITRO STUDIES OF A NEEDLE-TYPE GLUCOSE SENSOR FOR SUBCUTANEOUS MONITORING
    BINDRA, DS
    ZHANG, YN
    WILSON, GS
    STERNBERG, R
    THEVENOT, DR
    MOATTI, D
    REACH, G
    [J]. ANALYTICAL CHEMISTRY, 1991, 63 (17) : 1692 - 1696
  • [4] SUBCUTANEOUS IMPLANTATION OF A FERROCENE-MEDIATED GLUCOSE SENSOR IN PIGS
    CLAREMONT, DJ
    SAMBROOK, IE
    PENTON, C
    PICKUP, JC
    [J]. DIABETOLOGIA, 1986, 29 (11) : 817 - 821
  • [5] CLARKE WL, 1987, DIABETES CARE, V5, P622
  • [6] EGE H, 1989, Artificial Organs, V13, P171
  • [7] ASSESSMENT OF SUBCUTANEOUS GLUCOSE-CONCENTRATION - VALIDATION OF THE WICK TECHNIQUE AS A REFERENCE FOR IMPLANTED ELECTROCHEMICAL SENSORS IN NORMAL AND DIABETIC DOGS
    FISCHER, U
    ERTLE, R
    ABEL, P
    REBRIN, K
    BRUNSTEIN, E
    VONDORSCHE, HH
    FREYSE, EJ
    [J]. DIABETOLOGIA, 1987, 30 (12) : 940 - 945
  • [8] Fischer U, 1990, Journ Annu Diabetol Hotel Dieu, P247
  • [9] KERNER W, 1989, ARTIF ORGANS, V13, P173
  • [10] INVIVO BEHAVIOR OF HYPODERMICALLY IMPLANTED MICROFABRICATED GLUCOSE SENSORS
    KOUDELKA, M
    ROHNERJEANRENAUD, F
    TERRETTAZ, J
    BOBBIONIHARSCH, E
    DEROOIJ, NF
    JEANRENAUD, B
    [J]. BIOSENSORS & BIOELECTRONICS, 1991, 6 (01) : 31 - 36