BONE RESPONSE TO SURFACE-MODIFIED TITANIUM IMPLANTS - STUDIES ON ELECTROPOLISHED IMPLANTS WITH DIFFERENT OXIDE THICKNESSES AND MORPHOLOGY

被引:209
作者
LARSSON, C [1 ]
THOMSEN, P [1 ]
LAUSMAA, J [1 ]
RODAHL, M [1 ]
KASEMO, B [1 ]
ERICSON, LE [1 ]
机构
[1] CHALMERS UNIV TECHNOL,DEPT APPL PHYS,S-41296 GOTHENBURG,SWEDEN
关键词
TITANIUM; SURFACE ANALYSIS; MORPHOMETRY; BONE; OXIDE; SURFACE TOPOGRAPHY;
D O I
10.1016/0142-9612(94)90092-2
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
In a series of experimental studies, bone formation was analysed around systematically modified titanium implants. In the present study, machined, electropolished and anodically oxidized implants were prepared, surface characterized and inserted in the cortical bone of rabbits (7 wks and 12 wks). SEM, scanning Auger electron spectroscopy and atomic force microscopy revealed no differences in surface composition but marked differences in oxide thickness, surface topography and roughness. Light microscopic morphology and morphometry showed that all implants were in contact with bone, and had a large proportion of bone within the threads. The smooth, electropolished implants were surrounded by less bone than the machined implants with similar oxide thickness, (4-5 nm) and the anodically oxidized implants with thicker oxides (21 nm and 180 nm, respectively) after 7 wks. These studies show that a high degree of bone contact and bone formation can be achieved with titanium implants which are modified with respect to oxide thickness and surface topography. However, it appears that a reduction of surface roughness may influence the rate of bone formation in rabbit cortical bone.
引用
收藏
页码:1062 / 1074
页数:13
相关论文
共 31 条
[1]   MICROSTRUCTURE AND MORPHOLOGY OF SURFACE OXIDE-FILMS ON TI-6AL-4V [J].
ASK, M ;
ROLANDER, U ;
LAUSMAA, J ;
KASEMO, B .
JOURNAL OF MATERIALS RESEARCH, 1990, 5 (08) :1662-1667
[2]  
ASK M, 1988, APPL SURF SCI, V35, P283
[3]   CHARACTERIZATION OF SURFACE-ROUGHNESS IN TITANIUM DENTAL IMPLANTS MEASURED WITH SCANNING TUNNELING MICROSCOPY AT ATMOSPHERIC-PRESSURE [J].
BARO, AM ;
GARCIA, N ;
MIRANDA, R ;
VAZQUEZ, L ;
APARICIO, C ;
OLIVE, J ;
LAUSMAA, J .
BIOMATERIALS, 1986, 7 (06) :463-466
[4]  
Breine U., 1977, OSSEOINTEGRATED IMPL
[5]  
Brunette D M, 1988, Int J Oral Maxillofac Implants, V3, P231
[6]   STUDY OF TITANIUM-OXIDES USING AUGER LINE-SHAPES [J].
DAVIS, GD ;
NATAN, M ;
ANDERSON, KA .
APPLIED SURFACE SCIENCE, 1983, 15 (1-4) :321-333
[7]  
DAVIS LE, 1978, HDB AUGER ELECT SPEC, P5
[8]   A METHOD FOR THE STUDY OF UNDECALCIFIED BONES AND TEETH WITH ATTACHED SOFT-TISSUES - THE SAGE-SCHLIFF (SAWING AND GRINDING) TECHNIQUE [J].
DONATH, K ;
BREUNER, G .
JOURNAL OF ORAL PATHOLOGY & MEDICINE, 1982, 11 (04) :318-326
[9]  
ERICSON LE, 1991, BONE-BIOMATERIAL INTERFACE, P425
[10]   SCANNING PROBE METROLOGY [J].
GRIFFITH, JE ;
GRIGG, DA ;
VASILE, MJ ;
RUSSELL, PE ;
FITZGERALD, EA .
JOURNAL OF VACUUM SCIENCE & TECHNOLOGY A-VACUUM SURFACES AND FILMS, 1992, 10 (04) :674-679