PROPAGATION CONSTANT DETERMINATION IN MICROWAVE FIXTURE DE-EMBEDDING PROCEDURE

被引:47
作者
MONDAL, JP
CHEN, TH
机构
[1] GE, Syracuse, NY, USA, GE, Syracuse, NY, USA
关键词
MICROWAVE MEASUREMENTS - Attenuation;
D O I
10.1109/22.3575
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
An improper choice of dimensions for the standards used in the microwave de-embedding procedure will cause errors in the determination of the propagation constant. This leads to unrealistic values for the attenuation constant, which in turn causes errors in the de-embedded results. Proper selection of dimensions is made to minimize such errors. Physically realistic values are obtained with this selection.
引用
收藏
页码:706 / 714
页数:9
相关论文
共 12 条
[1]   LAUNCHER AND MICROSTRIP CHARACTERIZATION [J].
BIANCO, B ;
PARODI, M ;
RIDELLA, S ;
SELVAGGI, F .
IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 1976, 25 (04) :320-323
[2]  
CURRAN J, 1986, SEP HEWL PACK RF MIC
[3]  
Franzen N. R., 1975, 5th European Microwave Conference, P69
[4]  
GUPTA KC, 1979, MICROSTRIP LINES STO, P35
[5]  
HILLBUN M, 1980, MICROWAVE SYSTEM MAR, P83
[7]   ACCURATE MODEL FOR OPEN END EFFECT OF MICROSTRIP LINES [J].
KIRSCHNING, M ;
JANSEN, RH ;
KOSTER, NHL .
ELECTRONICS LETTERS, 1981, 17 (03) :123-124
[8]   LOSSES IN MICROSTRIP [J].
PUCEL, RA ;
MASSE, DJ ;
HARTWIG, CP .
IEEE TRANSACTIONS ON MICROWAVE THEORY AND TECHNIQUES, 1968, MT16 (06) :342-&
[9]  
ROSENBAUM SE, 1986, 27TH AUT RF TECH C, P148