STUDIES ON A NEW CROSS-AXIS COIL PLANET CENTRIFUGE FOR PERFORMING COUNTERCURRENT CHROMATOGRAPHY .1. DESIGN OF THE APPARATUS, RETENTION OF THE STATIONARY-PHASE, AND EFFICIENCY IN THE SEPARATION OF PROTEINS WITH POLYMER PHASE SYSTEMS

被引:53
作者
SHINOMIYA, K [1 ]
MENET, JM [1 ]
FALES, HM [1 ]
ITO, Y [1 ]
机构
[1] NHLBI,BIOPHYS CHEM LAB,BLDG 10,ROOM 7N322,BETHESDA,MD 20892
来源
JOURNAL OF CHROMATOGRAPHY | 1993年 / 644卷 / 02期
关键词
D O I
10.1016/0021-9673(93)80703-B
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
An improved model of the cross-axis synchronous flow-through coil planet centrifuge has been designed in light of previous studies. The apparatus has a versatile feature in that both analytical and preparative columns can be accommodated in both off-center and central positions. Each has merit in separations. Retention of stationary phase was examined with various two-phase solvent systems used for the separation of biopolymers. Both analytical and preparative columns showed satisfactory retention of the stationary phase under optimum conditions. The apparatus was evaluated in separation of a set of protein samples using a polyethylene glycol-potassium phosphate biphasic system. In both types of columns all proteins were resolved with partition efficiencies of 260 to 670 theoretical plates. Further studies indicated that the relatively low partition efficiency of proteins is mainly attributed to their high molecular mass or molecular heterogeneity within each species rather than due to the high viscosity of the polymer phase system.
引用
收藏
页码:215 / 229
页数:15
相关论文
共 14 条
[1]  
Albertsson P., 1986, PARTITION CELL PARTI
[2]  
Conway WD., 1990, COUNTERCURRENT CHROM
[3]  
HURST E, 1978, ANAL BIOCHEM, V85, P230
[4]   HIGH-SPEED COUNTERCURRENT CHROMATOGRAPHY [J].
ITO, Y .
CRC CRITICAL REVIEWS IN ANALYTICAL CHEMISTRY, 1986, 17 (01) :65-143
[5]   CROSS-AXIS SYNCHRONOUS FLOW-THROUGH COIL PLANET CENTRIFUGE FOR LARGE-SCALE PREPARATIVE COUNTERCURRENT CHROMATOGRAPHY .2. STUDIES ON PARTITION EFFICIENCY IN SHORT COILS AND PREPARATIVE SEPARATIONS WITH MULTILAYER COILS [J].
ITO, Y ;
ZHANG, TY .
JOURNAL OF CHROMATOGRAPHY, 1988, 449 (01) :153-164
[6]   CROSS-AXIS SYNCHRONOUS FLOW-THROUGH COIL PLANET CENTRIFUGE FREE OF ROTARY SEALS FOR PREPARATIVE COUNTERCURRENT CHROMATOGRAPHY .1. APPARATUS AND ANALYSIS OF ACCELERATION [J].
ITO, Y .
SEPARATION SCIENCE AND TECHNOLOGY, 1987, 22 (8-10) :1971-1987
[7]   CROSS-AXIS SYNCHRONOUS FLOW-THROUGH COIL PLANET CENTRIFUGE FREE OF ROTARY SEALS FOR PREPARATIVE COUNTERCURRENT CHROMATOGRAPHY .2. STUDIES ON PHASE DISTRIBUTION AND PARTITION EFFICIENCY IN COAXIAL COILS [J].
ITO, Y .
SEPARATION SCIENCE AND TECHNOLOGY, 1987, 22 (8-10) :1989-2009
[8]  
ITO Y, 1991, J CHROMATOGR, V538, P814
[9]   PURIFICATION OF URIDINE PHOSPHORYLASE FROM CRUDE EXTRACTS OF ESCHERICHIA-COLI EMPLOYING HIGH-SPEED COUNTERCURRENT CHROMATOGRAPHY WITH AN AQUEOUS 2-PHASE SOLVENT SYSTEM [J].
LEE, YW ;
SHIBUSAWA, Y ;
CHEN, FT ;
MYERS, J ;
SCHOOLER, JM ;
ITO, Y .
JOURNAL OF LIQUID CHROMATOGRAPHY, 1992, 15 (15-16) :2831-2841
[10]  
MANDAVA NB, 1988, COUNTERCURRENT CHROM