DEVELOPMENT OF 2 NEW M-PI-N CDTE SENSORS

被引:26
作者
SQUILLANTE, MR
ENTINE, G
FREDERICK, E
CIRIGNANO, L
HAZLETT, T
机构
关键词
D O I
10.1016/0168-9002(89)91379-X
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
引用
收藏
页码:323 / 329
页数:7
相关论文
共 8 条
[1]   TIME-DEPENDENT POLARIZATION OF CDTE GAMMA-RAY DETECTORS [J].
BELL, RO ;
ENTINE, G ;
SERREZE, HB .
NUCLEAR INSTRUMENTS & METHODS, 1974, 117 (01) :267-271
[2]   FAST, HIGH-FLUX, PHOTO-VOLTAIC CDTE DETECTOR [J].
ENTINE, G ;
SQUILLANTE, MR ;
SERREZE, HB ;
CLARKE, E .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1981, 28 (01) :558-562
[3]   CDTE PHOTO-VOLTAIC GAMMA-RAY DOSIMETER [J].
FOX, RJ ;
AGOURIDIS, DC .
NUCLEAR INSTRUMENTS & METHODS, 1978, 157 (01) :65-69
[4]   LARGE, HIGH-RESOLUTION CDTE GAMMA-RAY SENSORS [J].
HAZLETT, T ;
COLE, H ;
SQUILLANTE, MR ;
ENTINE, G ;
SUGARS, G ;
FECYCH, W ;
TENCH, O .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1986, 33 (01) :332-335
[5]  
Knoll GF, 1979, RAD DETECTION MEASUR
[6]   POLARIZATION PHENOMENA IN CDTE NUCLEAR RADIATION DETECTORS [J].
MALM, HL ;
MARTINI, M .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1974, NS21 (01) :322-330
[7]   METHODS TO SUPPRESS POLARIZATION IN CHLORINE COMPENSATED CADMIUM TELLURIDE DETECTORS [J].
SIFFERT, P ;
HAGEALI, M ;
STUCK, R ;
CORNET, A .
REVUE DE PHYSIQUE APPLIQUEE, 1977, 12 (02) :335-338
[8]   CRYSTAL-GROWTH OF CDTE FOR GAMMA-RAY DETECTORS [J].
WALD, FV ;
ENTINE, G .
NUCLEAR INSTRUMENTS & METHODS, 1978, 150 (01) :13-23