MOTION-INSENSITIVE, STEADY-STATE FREE PRECESSION IMAGING

被引:128
作者
ZUR, Y
WOOD, ML
NEURINGER, LJ
机构
[1] MIT,FRANCIS BITTER NATL MAGNET LAB,CAMBRIDGE,MA 02139
[2] NEW ENGLAND MED CTR HOSP,DEPT RADIAT ONCOL,BOSTON,MA 02111
[3] TUFTS UNIV,BOSTON,MA 02111
关键词
D O I
10.1002/mrm.1910160311
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Steady‐state free precession (SSFP) pulse sequences employing gradient reversal echoes and short repetition time (TR) between successive rf excitation pulses offer high signal‐to‐noise ratio per unit time. However, SSFP sequences are very sensitive to motion. A new SSFP method is presented which avoids the image artifacts and loss of signal intensity due to motion. The pulse sequence is designed so that the time integral of each of the three gradients is zero over each TR time interval. The signal then consists of numerous echoes which are superimposed. These echoes are isolated by combining the data from N different scans. In each scan a specific phase shift is added during every TR interval. Each of these N isolated echoes produces a motion‐insensitive, artifact‐free image. Because all the echoes are sampled simultaneously, the signal‐to‐noise ratio per unit time in this SSFP method is higher than in existing SSFP techniques which sample only one echo at a time. The new method was implemented and used to produce both two‐ and three‐dimensional images of the head and cervical spin of a human patient. In these images the high signal intensity of cerebrospinal fluid is preserved regardless of its motion. Further work is required to evaluate the imaging parameters (TR, TE, rf tip angle) so as to give optimal tissue contrast for the various echoes. © 1990 Academic Press, Inc. Copyright © 1990 Wiley‐Liss, Inc., A Wiley Company
引用
收藏
页码:444 / 459
页数:16
相关论文
共 22 条
[11]   MRI OF DIFFUSION IN THE HUMAN-BRAIN - NEW RESULTS USING A MODIFIED CE-FAST SEQUENCE [J].
MERBOLDT, KD ;
BRUHN, H ;
FRAHM, J ;
GYNGELL, ML ;
HANICKE, W ;
DEIMLING, M .
MAGNETIC RESONANCE IN MEDICINE, 1989, 9 (03) :423-429
[12]  
OPPELT A, 1986, Electromedica (English Edition), V54, P15
[13]   MOTION ARTIFACT SUPPRESSION TECHNIQUE (MAST) FOR MR IMAGING [J].
PATTANY, PM ;
PHILLIPS, JJ ;
CHIU, LC ;
LIPCAMON, JD ;
DUERK, JL ;
MCNALLY, JM ;
MOHAPATRA, SN .
JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 1987, 11 (03) :369-377
[14]   THE APPLICATION OF STEADY-STATE FREE PRECESSION TO THE STUDY OF VERY SLOW FLUID-FLOW [J].
PATZ, S ;
HAWKES, RC .
MAGNETIC RESONANCE IN MEDICINE, 1986, 3 (01) :140-145
[16]   FADE - A NEW FAST IMAGING SEQUENCE [J].
REDPATH, TW ;
JONES, RA .
MAGNETIC RESONANCE IN MEDICINE, 1988, 6 (02) :224-234
[18]  
UTZ J A, 1986, Magnetic Resonance Imaging, V4, P106, DOI 10.1016/0730-725X(86)90917-3
[19]  
WIELOPOLSKI PA, 1989, SMRM BOOK ABSTRACTS, P846
[20]   EFFECTS OF DIFFUSION IN NUCLEAR MAGNETIC RESONANCE SPIN-ECHO EXPERIMENTS [J].
WOESSNER, DE .
JOURNAL OF CHEMICAL PHYSICS, 1961, 34 (06) :2057-&