Hypolimnetic aeration of Medical Lake, WA using partial lift and full lift aerator designs resulted in enhanced water quality. The partial lift system significantly reduced hypolimnetic ammonia (NH3) and total phosphorus (TP) concentrations and increased hypolimnetic temperature. The system had no statistically significant effect on chlorophyll a (Chl a) concentration, phytoplankton biovolume, hypolimnetic nitrate (NO3-) and dissolved oxygen (DO) concentrations. The full lift system also significantly reduced hypolimnetic TP and NH3 concentrations, but increased hypolimnetic DO and temperature. This system likewise had no effect on Chl a concentrations. Although anoxia persisted with the partial lift system, it was viewed as effective because phosphorus was not released from the lake's bottom, demonstrating that measurable concentrations of DO were not required to hold phosphorus in the sediments. Further research is required on (1) the effect of hypolimnetic aeration on stimulating DO depletion rates and (2) long term effects on phytoplankton biovolumes and Chl a concentrations. Continued operation of the full lift system should further reduce in situ oxygen demands and eventually a new equilibrium and higher hypolimnetic oxygen concentrations can be attained.
引用
收藏
页码:2297 / 2308
页数:12
相关论文
共 54 条
[1]  
[Anonymous], 2001, LIMNOLOGY, DOI DOI 10.1016/B978-0-08-057439-4.50019-8
[2]  
[Anonymous], 1989, STANDARD METHODS EXA
[3]  
[Anonymous], 1985, STANDARD METHODS EXA
[4]   HYPOLIMNETIC AERATION - PRACTICAL DESIGN AND APPLICATION [J].
ASHLEY, KI .
WATER RESEARCH, 1985, 19 (06) :735-740
[5]   HYPOLIMNETIC AERATION - FIELD-TEST OF THE EMPIRICAL SIZING METHOD [J].
ASHLEY, KI ;
HAY, S ;
SCHOLTEN, GH .
WATER RESEARCH, 1987, 21 (02) :223-227
[6]   EFFECTS OF ORIFICE SIZE AND SURFACE CONDITIONS ON OXYGEN-TRANSFER IN A BENCH SCALE DIFFUSED AERATION SYSTEM [J].
ASHLEY, KI ;
MAVINIC, DS ;
HALL, KJ .
ENVIRONMENTAL TECHNOLOGY, 1990, 11 (07) :609-618
[7]   FACTORS INFLUENCING OXYGEN-TRANSFER IN FINE PORE DIFFUSED AERATION [J].
ASHLEY, KI ;
HALL, KJ ;
MAVINIC, DS .
WATER RESEARCH, 1991, 25 (12) :1479-1486
[9]  
ASHLEY KI, 1990, VERH INT VEREIN LIMN, V24, P179
[10]  
ASHLEY KI, 1990, PRELIMINARY DESIGN H, P28