摘要
Paramagnetic compounds are often used to enhance contrast in MRI by virtue of their increase in the kinetics of the relaxation of water 1H magnetization. Here, we demonstrate a method for contrast enhancement which is based on the resonance frequency shifts caused by the bulk magnetic susceptibility (BMS) effects of such compounds. This involves the frequency selective excitation in the absence of field gradients, during the imaging sequence, of a portion of the water 1H resonance which is rendered inhomogeneous by BMS shifts only. The image which results is of that portion of the sample which gives rise to the portion of the spectrum excited. A phantom sample which simulates some aspects of tissue, particularly blood vessels with different orientations in the magnetic field, was prepared. The contrast enhancement exhibited here avoids some of the distortions attendant to the use of paramagnetic reagents. This new approach can, in principle, utilize the natural BMS differences found in all tissue. © 1990 Academic Press, Inc. Copyright © 1990 Wiley‐Liss, Inc., A Wiley Company
引用
收藏
页码:80 / 90
页数:11
相关论文
共 31 条
[11]   MULTIPLE CHEMICAL-SHIFT-SELECTIVE NMR IMAGING USING STIMULATED ECHOES [J].
HAASE, A ;
FRAHM, J .
JOURNAL OF MAGNETIC RESONANCE, 1985, 64 (01) :94-102
[12]   USE OF SOLVENT SUPPRESSION TECHNIQUE TO ENHANCE CHANGES DUE TO SUSCEPTIBILITY VARIATIONS IN MAGNETIC-RESONANCE IMAGING [J].
HALL, AS ;
COLLINS, AG ;
BRYANT, DJ ;
YOUNG, IR ;
BYDDER, GM .
MAGNETIC RESONANCE IN MEDICINE, 1989, 9 (03) :411-418
[13]   RAPID P-31 SPECTROSCOPY ON A 4-T WHOLE-BODY SYSTEM [J].
HARDY, CJ ;
BOTTOMLEY, PA ;
ROEMER, PB ;
REDINGTON, RW .
MAGNETIC RESONANCE IN MEDICINE, 1988, 8 (01) :104-109
[14]   GADOLINIUM-LABELED LIPOSOMES CONTAINING PARAMAGNETIC AMPHIPATHIC AGENTS - TARGETED MRI CONTRAST AGENTS FOR THE LIVER [J].
KABALKA, GW ;
BUONOCORE, E ;
HUBNER, K ;
DAVIS, M ;
HUANG, L .
MAGNETIC RESONANCE IN MEDICINE, 1988, 8 (01) :89-95
[15]   NA-23 CHEMICAL-SHIFT IMAGING [J].
KOHLER, SJ ;
SMITH, EK ;
KOLODNY, NH .
JOURNAL OF MAGNETIC RESONANCE, 1989, 83 (02) :423-427
[16]   PARAMAGNETIC METAL-COMPLEXES AS WATER PROTON RELAXATION AGENTS FOR NMR IMAGING - THEORY AND DESIGN [J].
LAUFFER, RB .
CHEMICAL REVIEWS, 1987, 87 (05) :901-927
[17]  
LAUTERBUR PC, 1986, 5TH ANN M SOC MAGN R, P229
[18]  
Ludeke K M, 1985, Magn Reson Imaging, V3, P329, DOI 10.1016/0730-725X(85)90397-2
[19]   SPATIALLY RESOLVED HIGH-RESOLUTION SPECTROSCOPY BY 4-DIMENSIONAL NMR [J].
MAUDSLEY, AA ;
HILAL, SK ;
PERMAN, WH ;
SIMON, HE .
JOURNAL OF MAGNETIC RESONANCE, 1983, 51 (01) :147-152
[20]  
McKinnon G, 1985, Magn Reson Imaging, V3, P417, DOI 10.1016/0730-725X(85)90406-0