SOLUTE ADSORPTION ON POLYMER-COATED FUSED-SILICA CAPILLARY ELECTROPHORESIS COLUMNS USING SELECTED PROTEIN AND PEPTIDE STANDARDS

被引:112
作者
ZHAO, ZX [1 ]
MALIK, A [1 ]
LEE, ML [1 ]
机构
[1] BRIGHAM YOUNG UNIV,DEPT CHEM,PROVO,UT 84602
关键词
D O I
10.1021/ac00068a008
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Three series of basic proteins and peptides were selected for use in studying the adsorption behavior of fused-silica capillary electrophoresis columns. A comparative study of untreated and treated fused-silica columns was done. The polymers used as coating materials ranged from very hydrophobic to very hydrophilic. The average efficiency of weakly hydrophilic Ucon-coated capillaries for basic proteins was over 1 million theoretical plates at a buffer pH of 4.8. For this coating, it was found that the maximum column efficiency was obtained at a film thickness of approximately 100 nm. It was easily seen that both ionic and hydrophobic interaction forces can play important roles in protein adsorption onto the capillary walls. Furthermore, strongly hydrophilic polymer coatings may possibly lead to hydrogen-bonding interactions, which decrease column efficiency. Studies have been conducted using two series of polypeptides with varying chain lengths. One series was used to study the effect of polypeptide chain length on retention behavior. Efficient separations of bioactive peptide drugs on Ucon-coated columns were achieved. The results indicate that high efficiency and resolution of basic peptides tested can be realized on columns modified with weakly hydrophilic polymers at a pH value of about 5.
引用
收藏
页码:2747 / 2752
页数:6
相关论文
共 45 条
[1]  
BECKER GW, 1988, BIOTECHNOL APPL BIOC, V10, P326
[2]   POLY(METHYLGLUTAMATE)-COATED SURFACES IN HPLC AND CE [J].
BENTROP, D ;
KOHR, J ;
ENGELHARDT, H .
CHROMATOGRAPHIA, 1991, 32 (3-4) :171-178
[3]   CAPILLARY ZONE ELECTROPHORETIC SEPARATIONS OF PROTEINS IN POLYETHYLENE GLYCOL-MODIFIED CAPILLARIES [J].
BRUIN, GJM ;
CHANG, JP ;
KUHLMAN, RH ;
ZEGERS, K ;
KRAAK, JC ;
POPPE, H .
JOURNAL OF CHROMATOGRAPHY, 1989, 471 :429-436
[4]   CAPILLARY ELECTROPHORESIS OF PROTEINS IN BUFFERS CONTAINING HIGH-CONCENTRATIONS OF ZWITTERIONIC SALTS [J].
BUSHEY, MM ;
JORGENSON, JW .
JOURNAL OF CHROMATOGRAPHY, 1989, 480 :301-310
[5]   ELECTROPHORETIC SEPARATIONS OF PROTEINS IN CAPILLARIES WITH HYDROLYTICALLY STABLE SURFACE-STRUCTURES [J].
COBB, KA ;
DOLNIK, V ;
NOVOTNY, M .
ANALYTICAL CHEMISTRY, 1990, 62 (22) :2478-2483
[6]   HIGH-SENSITIVITY PEPTIDE-MAPPING BY CAPILLARY ZONE ELECTROPHORESIS AND MICROCOLUMN LIQUID-CHROMATOGRAPHY, USING IMMOBILIZED TRYPSIN FOR PROTEIN DIGESTION [J].
COBB, KA ;
NOVOTNY, M .
ANALYTICAL CHEMISTRY, 1989, 61 (20) :2226-2231
[7]   PEPTIDE-MAPPING OF COMPLEX PROTEINS AT THE LOW-PICOMOLE LEVEL WITH CAPILLARY ELECTROPHORETIC SEPARATIONS [J].
COBB, KA ;
NOVOTNY, MV .
ANALYTICAL CHEMISTRY, 1992, 64 (08) :879-886
[8]   NEW METHOD FOR THE PREPARATION OF SMALL DIAMETER COLUMNS WITH POLYMERIC STATIONARY PHASES FOR OPEN TUBULAR LIQUID-CHROMATOGRAPHY [J].
DLUZNESKI, PR ;
JORGENSON, JW .
JOURNAL OF HIGH RESOLUTION CHROMATOGRAPHY & CHROMATOGRAPHY COMMUNICATIONS, 1988, 11 (04) :332-336
[9]  
EMMER A, 1991, HRC-J HIGH RES CHROM, V14, P738
[10]  
GOLDSTEIN A, 1983, PEPTIDES STRUCTURE F, P409