SHOULD INHOMOGENEITY CORRECTIONS BE APPLIED DURING TREATMENT PLANNING OF TANGENTIAL BREAST IRRADIATION

被引:10
作者
MIJNHEER, BJ
HEUKELOM, S
LANSON, JH
VANBATTUM, LJ
VANBREE, NAM
VANTIENHOVEN, G
机构
[1] DR DANIEL DENHOED CANC CTR,DEPT CLIN PHYS,ROTTERDAM,NETHERLANDS
[2] UNIV AMSTERDAM,ACAD MED CTR,DEPT RADIOTHERAPY,1105 AZ AMSTERDAM,NETHERLANDS
关键词
BREAST CANCER IRRADIATION; TREATMENT PLANNING; 3-DIMENSIONAL DOSE DISTRIBUTION; INVIVO DOSIMETRY; INHOMOGENEITY CORRECTIONS;
D O I
10.1016/0167-8140(91)90156-B
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Due to the inclusion of lung tissue in the treatment volume, some parts of the breast will get a higher dose during tangential breast irradiation because of the lower lung density. Data on the accuracy of dose calculation algorithms, investigated by phantom measurements, determinations of the geometry and density of the actual lung in the patient and the results of in vivo dose measurements, are presented. From this information it can be concluded that a lung correction varying between about 3% and 7% is needed but its magnitude is slightly over predicted in a number of commercial treatment planning systems. Because this increase in dose is already in a high dose region, it is recommended that inhomogeneity corrections should be applied during tangential breast irradiation.
引用
收藏
页码:239 / 244
页数:6
相关论文
共 20 条
[11]   INFLUENCE OF RADIATION-THERAPY ON THE LUNG-TISSUE IN BREAST-CANCER PATIENTS - CT-ASSESSED DENSITY CHANGES AND ASSOCIATED SYMPTOMS [J].
ROTSTEIN, S ;
LAX, I ;
SVANE, G .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1990, 18 (01) :173-180
[12]   3-DIMENSIONAL PHOTON TREATMENT PLANNING OF THE INTACT BREAST [J].
SOLIN, LJ ;
CHU, JCH ;
SONTAG, MR ;
BREWSTER, L ;
CHENG, E ;
DOPPKE, K ;
DRZYMALA, RE ;
HUNT, M ;
KUSKE, R ;
MANOLIS, JM ;
MCCORMICK, B ;
MUNZENRIDER, JE .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1991, 21 (01) :193-203
[13]   3-DIMENSIONAL DOSE DISTRIBUTION OF TANGENTIAL BREAST TREATMENT - A NATIONAL DOSIMETRY INTERCOMPARISON [J].
VANBREE, NAM ;
VANBATTUM, LJ ;
HUIZENGA, H ;
MIJNHEER, BJ .
RADIOTHERAPY AND ONCOLOGY, 1991, 22 (04) :252-260
[14]  
VANBREE NAM, 1990, 10TH P INT C US COMP
[15]   HALF BODY RADIOTHERAPY - THE USE OF COMPUTED-TOMOGRAPHY TO DETERMINE THE DOSE TO LUNG [J].
VANDYK, J ;
BATTISTA, JJ ;
RIDER, WD .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1980, 6 (04) :463-470
[16]   ACCURACY IN TANGENTIAL BREAST TREATMENT SET-UP - A PORTAL IMAGING STUDY [J].
VANTIENHOVEN, G ;
LANSON, JH ;
CRABEELS, D ;
HEUKELOM, S ;
MIJNHEER, BJ .
RADIOTHERAPY AND ONCOLOGY, 1991, 22 (04) :317-322
[17]   CLINICAL DOSIMETRY FOR RADIOTHERAPY TO THE BREAST BASED ON IMAGING WITH THE PROTOTYPE ROYAL-MARSDEN-HOSPITAL CT SIMULATOR [J].
WEBB, S ;
LEACH, MO ;
BENTLEY, RE ;
MAUREEMOOTOO, K ;
YARNOLD, JR ;
TOMS, MA ;
GARDINER, J ;
PARTON, D .
PHYSICS IN MEDICINE AND BIOLOGY, 1987, 32 (07) :835-845
[18]  
WESTERMANN C F, 1984, Radiotherapy and Oncology, V1, P339, DOI 10.1016/S0167-8140(84)80022-5
[19]   ON METHODS OF INHOMOGENEITY CORRECTIONS FOR PHOTON TRANSPORT [J].
WONG, JW ;
PURDY, JA .
MEDICAL PHYSICS, 1990, 17 (05) :807-814
[20]  
1991, INT J RADIAT ONCOL, V21, P59