THE IMPLEMENTATION OF PATIENT POSITION CORRECTION USING A MEGAVOLTAGE IMAGING DEVICE ON A LINEAR-ACCELERATOR

被引:11
作者
EVANS, PM
GILDERSLEVE, JQ
RAWLINGS, C
SWINDELL, W
机构
[1] ROYAL MARSDEN HOSP,JOINT DEPT PHYS,SUTTON SM2 5PT,SURREY,ENGLAND
[2] ROYAL MARSDEN HOSP,DEPT RADIOTHERAPY,SUTTON SM2 5PT,SURREY,ENGLAND
[3] INST CANC RES,SUTTON SM2 5PT,SURREY,ENGLAND
关键词
D O I
10.1259/0007-1285-66-789-833
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The problem of using information from the analysis of megavoltage images to adjust patient set-up has been addressed. In the case of rotational corrections it has been assumed that the treatment head is to be adjusted, although for gantry angles of 0° and 180° couch rotation may be used. In the case of translational shifts adjustment of the collimator jaws or of the couch have both been considered for arbitrary combinations of couch and gantry angle. For couch movement the case has been considered where it is desirable to minimize both the number of parameters to be adjusted and also the magnitude of the change in the patient's position. Values obtained for frequently used set-up parameters have been presented. Adjustment of the treatment couch positioning is the most desirable option, as this should bring the patient closer to the correct position for subsequent treatment fields. However, rotational errors are not correctable for all gantry angles and furthermore the collimator settings may be set more accurately than those of the treatment couch. Hence, in some cases, adjustment of the collimation system may be desirable or necessary. The formulae given in Equations (13) to (18) are currently being used in an intervention study to correct patient set-up during the course of a treatment fraction.
引用
收藏
页码:833 / 838
页数:6
相关论文
共 7 条
  • [1] FAST EVALUATION OF PATIENT SET-UP DURING RADIOTHERAPY BY ALIGNING FEATURES IN PORTAL AND SIMULATOR IMAGES
    BIJHOLD, J
    VANHERK, M
    VIJLBRIEF, R
    LEBESQUE, JV
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 1991, 36 (12) : 1665 - 1679
  • [2] IMAGE COMPARISON TECHNIQUES FOR USE WITH MEGAVOLTAGE IMAGING-SYSTEMS
    EVANS, PM
    GILDERSLEVE, JQ
    MORTON, EJ
    SWINDELL, W
    COLES, R
    FERRARO, M
    RAWLINGS, C
    XIAO, ZR
    DYER, J
    [J]. BRITISH JOURNAL OF RADIOLOGY, 1992, 65 (776) : 701 - 709
  • [3] DAILY MONITORING AND CORRECTION OF RADIATION-FIELD PLACEMENT USING A VIDEO-BASED PORTAL IMAGING-SYSTEM - A PILOT-STUDY
    EZZ, A
    MUNRO, P
    PORTER, AT
    BATTISTA, J
    JAFFRAY, DA
    FENSTER, A
    OSBORNE, S
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1992, 22 (01): : 159 - 165
  • [4] A METHOD TO ANALYZE 2-DIMENSIONAL DAILY RADIOTHERAPY PORTAL IMAGES FROM AN ONLINE FIBEROPTIC IMAGING-SYSTEM
    GRAHAM, ML
    CHENG, AY
    GEER, LY
    BINNS, WR
    VANNIER, MW
    WONG, JW
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1991, 20 (03): : 613 - 619
  • [5] ONLINE MEASUREMENT OF FIELD PLACEMENT ERRORS IN EXTERNAL BEAM RADIOTHERAPY
    LAM, WC
    PARTOWMAH, M
    LEE, DJ
    WHARAM, MD
    LAM, KS
    [J]. BRITISH JOURNAL OF RADIOLOGY, 1987, 60 (712) : 361 - 365
  • [6] A METHOD FOR THE MEASUREMENT OF FIELD PLACEMENT ERRORS IN DIGITAL PORTAL IMAGES
    MEERTENS, H
    BIJHOLD, J
    STRACKEE, J
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 1990, 35 (03) : 299 - 323
  • [7] REINSTEIN L, 1988, International Journal of Radiation Oncology, Biology, Physics, V15, P200