COMPARISON OF CAPTIVE AND PULSATING BUBBLE SURFACTOMETERS WITH USE OF LUNG SURFACTANTS

被引:77
作者
PUTZ, G
GOERKE, J
TAEUSCH, HW
CLEMENTS, JA
机构
[1] UNIV CALIF SAN FRANCISCO,CARDIOVASC RES INST,SAN FRANCISCO,CA 94143
[2] UNIV CALIF SAN FRANCISCO,DEPT PHYSIOL,SAN FRANCISCO,CA 94143
[3] UNIV CALIF SAN FRANCISCO,DEPT PEDIAT,SAN FRANCISCO,CA 94143
[4] UNIV CALIF LOS ANGELES,LOS ANGELES,CA 90059
[5] UNIV CALIF LOS ANGELES,DREW COLL MED,DEPT PEDIAT,LOS ANGELES,CA 90059
关键词
SURFACE TENSION; PULMONARY SURFACTANTS;
D O I
10.1152/jappl.1994.76.4.1425
中图分类号
Q4 [生理学];
学科分类号
071003 ;
摘要
We compared surface tension measures of surfactants with various surface activities by using a pulsating bubble surfactometer (PBS) and a captive bubble surfactometer (CBS). Rabbit lung lavage surfactant (60,000 X average g for 60 min), bovine surfactant extract (Survanta), and a synthetic lipid surfactant mixture (dipalmitoylphosphatidylcholine-egg phosphatidylglycerol-palmitic acid) were studied at 1.25 mg phospholipid/ml. The PBS was used either unmodified according to manufacturer's instructions or with the sample chamber capillary kept dry and the sample adsorbing at maximum bubble size (5 min). The CBS was used in a manner that imitated the unmodified PBS. We found that all three techniques indicated low surface tension on the first cycle for 60K. For Survanta, the CBS and the modified PBS reported low surface tension on the first cycle, whereas the unmodified PBS did not achieve this within 10 cycles. For the synthetic lipid surfactant mixture, only the CBS measured low surface tension within 10 cycles. Video observations indicate that the modified PBS performs better than the unmodified PBS because keeping the capillary dry prevents surface film from occupying this large surface during cycling, thereby allowing larger area compressions.
引用
收藏
页码:1425 / 1431
页数:7
相关论文
共 23 条
[11]  
Goerke J., 1986, HDB PHYSL RESP SYSTE, P247
[12]   PULMONARY SURFACE-FILM STABILITY AND COMPOSITION [J].
HILDEBRAN, JN ;
GOERKE, J ;
CLEMENTS, JA .
JOURNAL OF APPLIED PHYSIOLOGY, 1979, 47 (03) :604-611
[13]   INTERACTIONS BETWEEN PLASMA-PROTEINS AND PULMONARY SURFACTANT - PULSATING BUBBLE STUDIES [J].
KEOUGH, KMW ;
PARSONS, CS ;
TWEEDDALE, MG .
CANADIAN JOURNAL OF PHYSIOLOGY AND PHARMACOLOGY, 1989, 67 (06) :663-668
[14]   INTERFACIAL-TENSION FROM HEIGHT AND DIAMETER OF A SINGLE SESSILE DROP OR CAPTIVE BUBBLE [J].
MALCOLM, JD ;
ELLIOTT, CD .
CANADIAN JOURNAL OF CHEMICAL ENGINEERING, 1980, 58 (02) :151-153
[15]   VENTILATORY AND CHOLINERGIC CONTROL OF PULMONARY SURFACTANT IN RABBIT [J].
OYARZUN, MJ ;
CLEMENTS, JA .
JOURNAL OF APPLIED PHYSIOLOGY, 1977, 43 (01) :39-45
[16]   EVALUATION OF PRESSURE-DRIVEN CAPTIVE BUBBLE SURFACTOMETER [J].
PUTZ, G ;
GOERKE, J ;
SCHURCH, S ;
CLEMENTS, JA .
JOURNAL OF APPLIED PHYSIOLOGY, 1994, 76 (04) :1417-1424
[17]   DIRECT DETERMINATION OF VOLUME-DEPENDENCE AND TIME-DEPENDENCE OF ALVEOLAR SURFACE-TENSION IN EXCISED LUNGS [J].
SCHURCH, S ;
GOERKE, J ;
CLEMENTS, JA .
PROCEEDINGS OF THE NATIONAL ACADEMY OF SCIENCES OF THE UNITED STATES OF AMERICA, 1978, 75 (07) :3417-3421
[18]   A CAPTIVE BUBBLE METHOD REPRODUCES THE INSITU BEHAVIOR OF LUNG SURFACTANT MONOLAYERS [J].
SCHURCH, S ;
BACHOFEN, H ;
GOERKE, J ;
POSSMAYER, F .
JOURNAL OF APPLIED PHYSIOLOGY, 1989, 67 (06) :2389-2396
[19]   SURFACE-TENSION AT LOW LUNG-VOLUMES - DEPENDENCE ON TIME AND ALVEOLAR SIZE [J].
SCHURCH, S .
RESPIRATION PHYSIOLOGY, 1982, 48 (03) :339-355
[20]  
TANAKA Y, 1986, J LIPID RES, V27, P475