MODULATION OF BONE LOSS DURING DISUSE BY PULSED ELECTROMAGNETIC-FIELDS

被引:50
作者
SKERRY, TM
PEAD, MJ
LANYON, LE
机构
[1] UNIV LONDON ROYAL VET COLL,DEPT VET BASIC SCI,LONDON NW1 0TU,ENGLAND
[2] UNIV BRISTOL,DEPT ANAT,COMPARAT ORTHOPAED RES UNIT,BRISTOL BS8 1TH,AVON,ENGLAND
基金
英国惠康基金;
关键词
PULSED ELECTROMAGNETIC FIELDS; SURFACE MODELING REMODELING; INTRACORTICAL REMODELING; DISUSE OSTEOPENIA;
D O I
10.1002/jor.1100090417
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
The effect of pulsed electromagnetic fields (PEMFs) on bone loss associated with disuse was investigated by applying 1.5 Hz repetitions of 30 ms bursts of asymmetric pulses, varying from +2.5 to -135 mV, to bones deprived of their normal functional loading. The proximal portion of one fibula in each of a group of ovariectomised adult female beagle dogs was isolated from functional loading in vivo by proximal and distal osteotomies. Comparison of these prepared bones with their intact contralateral controls after 12 weeks, showed a 23% reduction in cross-sectional area. In similarly prepared bones exposed to PEMFs for 1 h per day, 5 days per week, this bone loss was substantially and significantly reduced to 9% (p = 0.029). There was no evidence of any new bone formation on the periosteal surface of prepared fibulae in treated or untreated situations. PEMF treatment was not associated with any significant change in number of osteons per mm2 formed within the cortex of the bones, their radial closure rate, or their degree of closure. The modulation in loss of bone area associated with exposure to PEMFs can, therefore, be inferred to be due to a reduction in resorption on the bone surface.
引用
收藏
页码:600 / 608
页数:9
相关论文
共 23 条
[1]   EFFECTS OF ELECTRIC CURRENTS ON BONE IN VIVO [J].
BASSETT, CA ;
PAWLUK, RJ ;
BECKER, RO .
NATURE, 1964, 204 (495) :652-&
[2]  
BASSETT CAL, 1984, ORTHOP CLIN N AM, V15, P61
[3]  
BASSETT CAL, 1979, ELECTRICAL PROPERTIE, P427
[4]   TREATMENT OF DENERVATION DISUSE OSTEOPOROSIS IN THE RAT WITH A CAPACITIVELY COUPLED ELECTRICAL SIGNAL - EFFECTS ON BONE-FORMATION AND BONE-RESORPTION [J].
BRIGHTON, CT ;
TADDUNI, GT ;
GOLL, SR ;
POLLACK, SR .
JOURNAL OF ORTHOPAEDIC RESEARCH, 1988, 6 (05) :676-684
[5]   DIRECT-CURRENT STIMULATION OF NON-UNION AND CONGENITAL PSEUDARTHROSIS - EXPLORATION OF ITS CLINICAL APPLICATION [J].
BRIGHTON, CT ;
FRIEDENBERG, ZB ;
ZEMSKY, LM ;
POLLIS, PR .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1975, A 57 (03) :368-377
[6]   PREVENTION AND TREATMENT OF SCIATIC DENERVATION DISUSE OSTEOPOROSIS IN THE RAT TIBIA WITH CAPACITIVELY COUPLED ELECTRICAL-STIMULATION [J].
BRIGHTON, CT ;
KATZ, MJ ;
GOLL, SR ;
NICHOLS, CE ;
POLLACK, SR .
BONE, 1985, 6 (02) :87-97
[7]   PROLIFERATIVE AND SYNTHETIC RESPONSE OF BOVINE GROWTH PLATE CHONDROCYTES TO VARIOUS CAPACITIVELY COUPLED ELECTRICAL FIELDS [J].
BRIGHTON, CT ;
JENSEN, L ;
POLLACK, SR ;
TOLIN, BS ;
CLARK, CC .
JOURNAL OF ORTHOPAEDIC RESEARCH, 1989, 7 (05) :759-765
[8]  
BRIGHTON CT, 1984, ORTHOP CLIN N AM, V15, P33
[9]  
BRIGHTON CT, 1985, J BONE JOINT SURG AM, V64, P1022
[10]   ON THE PIEZOELECTRIC EFFECT OF BONE [J].
FUKADA, E ;
YASUDA, I .
JOURNAL OF THE PHYSICAL SOCIETY OF JAPAN, 1957, 12 (10) :1158-1162