DETERMINATION OF PARACETAMOL AND ITS 4 MAJOR METABOLITES IN MOUSE PLASMA BY REVERSED-PHASE ION-PAIR HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY

被引:35
作者
ESTEBAN, A
GRAELLS, M
SATORRE, J
PEREZMATEO, M
机构
[1] HOSP GEN ELCHE,DIV CLIN BIOCHEM,ALICANTE,SPAIN
[2] HOSP GEN ELCHE,DEPT INTERNAL MED,ALICANTE,SPAIN
来源
JOURNAL OF CHROMATOGRAPHY-BIOMEDICAL APPLICATIONS | 1992年 / 573卷 / 01期
关键词
D O I
10.1016/0378-4347(92)80483-7
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A reversed-phase ion-pair high-performance liquid chromatographic method has been used for the separation of paracetamol and its four major metabolites (glucuronide, sulphate, cysteine and mercapturate conjugates) in mouse plasma samples. An ODS column was used and the mobile phase consisted of an aqueous solution of 0.01 M tetrabutylammonium chloride and 0.01 M Tris buffered to pH 5.0 with phosphoric acid, with methanol as the organic solvent. The gradient elution started with 30% methanol. After a delay of 0.5 min the methanol concentration was increased linearly to 75% over 7.5 min. The column was returned to the intial conditions after a delay of 1 min. A methanol solution of theophylline was added to the mouse sample, centrifuged and immediately injected into the chromatographic system. The advantages of this method include good and rapid separation (last metabolite detected at 6.86 min), well resolved peaks, only a small amount of sample required for assay, adequate precision (no coefficient of variation was greater than 10% for paracetamol metabolites) and a high sensitivity (particularly for unchanged paracetamol and the cysteine conjugate).
引用
收藏
页码:121 / 126
页数:6
相关论文
共 22 条