A NEW COMBINED INTEGRAL-LIGHT AND SLIT-SCAN DATA-ANALYSIS SYSTEM (DAS) FOR FLOW-CYTOMETRY

被引:47
作者
BEISKER, W
机构
[1] GSF-Institut für Biophysikalische Strahlenforschung, Neuherberg, D-85764 Oberschleissheim
关键词
FLOW CYTOMETRY; SLIT-SCAN; MULTIPARAMETER DATA ANALYSIS AND GRAPHICS; PC;
D O I
10.1016/0169-2607(94)90134-1
中图分类号
TP39 [计算机的应用];
学科分类号
081203 ; 0835 ;
摘要
Flow cytometry using list mode parameters such as fluorescence emission, light scatter and size on one hand and different slit-scan parameters on the other hand needs a fast, flexible, efficient and easy-to-use data analysis software. A new software package (data analysis system, DAS) has been developed that integrates data analysis for conventional (integral-light) flow cytometry and for slit-scan flow cytometry. The requirements, design and some examples are discussed and an implementation for IBM-compatible computers is presented. Special attention is directed to the handling of different data types from one-parameter histograms to multiparameter slit-scan data files. The package can be used as an interpreting programming language or as an interactive menu-driven command line interpreter with a large number of graphic, mathematical and statistical functions. DAS is not limited to use in flow cytometry only, but multidimensional data analysis, from astronomy to economics, can be done as well.
引用
收藏
页码:15 / 26
页数:12
相关论文
共 24 条
  • [1] CONVERSION OF LINEAR HISTOGRAM FLOW-CYTOMETRY DATA TO A LOGARITHMIC DISPLAY
    BRUNK, CF
    BOHMAN, RE
    BRUNK, CA
    [J]. CYTOMETRY, 1982, 3 (02): : 138 - 141
  • [2] MACINTOSH GRAPHICS FOR THE EPICS FLOW CYTOMETER USER
    CAMERON, MJ
    [J]. CYTOMETRY, 1990, 11 (08): : 916 - 918
  • [3] HIGH-RESOLUTION OPTICS COMBINED WITH HIGH SPATIAL REPRODUCIBILITY IN FLOW
    EISERT, WG
    [J]. CYTOMETRY, 1981, 1 (04): : 254 - 259
  • [4] CUBIC - A 3-DIMENSIONAL COLORED PROJECTION OF CONSORT 30 GENERATED TRIVARIATE FLOW CYTOMETRIC DATA
    GREIMERS, R
    RONGY, AM
    SCHAAFLAFONTAINE, N
    BONIVER, J
    [J]. CYTOMETRY, 1991, 12 (06): : 570 - 578
  • [5] HAUSMANN M, 1991, Z NATURFORSCH C, V46, P433
  • [6] INTRAPHAGOLYSOSOMAL PH IN CANINE AND RAT ALVEOLAR MACROPHAGES - FLOW CYTOMETRIC MEASUREMENTS
    HEILMANN, P
    BEISKER, W
    MIASKOWSKI, U
    CAMNER, P
    KREYLING, WG
    [J]. ENVIRONMENTAL HEALTH PERSPECTIVES, 1992, 97 : 115 - 120
  • [7] ONLINE 3-PARAMETER DATA UPTAKE, ANALYSIS, AND DISPLAY DEVICE FOR FLOW-CYTOMETRY AND OTHER APPLICATIONS
    KACHEL, V
    SCHNEIDER, H
    [J]. CYTOMETRY, 1986, 7 (01): : 25 - 40
  • [8] 8-PARAMETER PC-AT BASED FLOW CYTOMETRIC DATA SYSTEM
    KACHEL, V
    MESSERSCHMIDT, R
    HUMMEL, P
    [J]. CYTOMETRY, 1990, 11 (07): : 805 - 812
  • [9] CENTROMERIC INDEX MEASUREMENT BY SLIT-SCAN FLOW-CYTOMETRY
    LUCAS, JN
    GRAY, JW
    PETERS, DC
    VANDILLA, MA
    [J]. CYTOMETRY, 1983, 4 (02): : 109 - 116
  • [10] DICENTRIC CHROMOSOME FREQUENCY-ANALYSIS USING SLIT-SCAN FLOW-CYTOMETRY
    LUCAS, JN
    MULLIKIN, JC
    GRAY, JW
    [J]. CYTOMETRY, 1991, 12 (04): : 316 - 322